OMRON
Home >> Download >> OMRON >> Manual Download >> E3S-R66 INSTRUCTION sheet ()

E3S-R66 INSTRUCTION sheet ()

Brand: OMRON
Product model: E3S-R66
Name: photoelectric sensors
Sort: INSTRUCTION sheet
File language: English
File size: 10.23MB
Size: 48 x 48mm.
Body: terminal type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The failure detection function of the heater with the broken line and SSR: - E3S-R66 INSTRUCTION sheet.
Event input points: - E3S-R66
Transfer output: transfer output (special terminal).
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0 E3S-R66 INSTRUCTION sheet. 01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer E3S-R66 INSTRUCTION sheet. 4.0) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay faultE32-T16 type: special beam type; region detection,
Specialty: regional width 10mm long distance,
Shape / detection distance (mm): 3700; 2800; 1850 (740),
Bending radius (mm): R25.
Standard test object (minimum test object) (mm) 1: (0.6) 4,
Fiber element for meeting diversified needsSize: DIN 1/16, 48 X 48 x 60mm.
Powwer supply voltage: AC100 ~ 240V E3S-R66 Manual.
Input type: thermocouple.
Alarm points: -.
Control output: voltage output (for driving SSR).
Simple new temperature controller, easy to achieve temperature control.
Good visibility (character height EE5CSL:21 E3S-R66 Manual. 7mm, E5CWL:16.2mm (PV), E5EWL:20mm (PV)).
From the front panel depth: 60mm.
Parameter is less, set simple.
Sampling time was reduced to 250ms.
Related products
OMRON
Built-in Amplifier Photoelectric Sensor
E3S-AD37
OMRON Built-in Amplifier Photoelectric Sensor E3S-AD37
Sensing method: Diffuse-reflective Sensors.
OMRON
Amplifier built-in type photoelectric switch
E3S-BT11
OMRON Amplifier built-in type photoelectric switch E3S-BT11
Small, easy to use. Detection mode: on the ra
OMRON
Built-in Amplifier Photoelectric Sensor
E3S-AD91
OMRON Built-in Amplifier Photoelectric Sensor E3S-AD91
Sensing method: Diffuse-reflective Sensors.