OMRON
Home >> Download >> OMRON >> Manual Download >> E3T-SR44-M1TJ INSTRUCTION sheet ()

E3T-SR44-M1TJ INSTRUCTION sheet ()

Brand: OMRON
Product model: E3T-SR44-M1TJ
Name: photoelectric sensors
Sort: INSTRUCTION sheet
File language: English
File size: 0.70MB
Size: M12 (brass), single distance, shielding type.
Detection range: 2mm.
Connection mode: lead type (cable length is 2M and 5m two).
Thread length: long thread type.
Output type: PNP.
Action mode NO.
Set up the new standard of the world economy proximity sensor.
OMRON as a pioneer and leader in proximity sensor industry,
Now bring you a new E2B proximity sensor with high performance to price ratio E3T-SR44-M1TJ INSTRUCTION sheet E3T-SR44-M1TJ
This series of products are complete,
Aimed at reasonable prices to meet customer demand for high quality and high reliability of the sensor.
We have tested the product not only on the protection level (IP67) specific item,
The oil spray test was carried out on the condition of the work site.
Simulation test was carried out in the environment of high oil mist concentration E3T-SR44-M1TJ INSTRUCTION sheet. Ontology: DeviceNet type.
Size: 48 x 96mm.
Type: basic type (1 input)
Control mode: standard control, heating and cooling control.
Output (control / transfer) points: 2 point (pulse voltage + pulse voltage / current).
Output (SUB) points: 2 points.
Event entry point: 2.
High speed, high precision and multiple input and output universal digital regulator,
Liquid crystal display device with high visibility 5 bit and 3 line E3T-SR44-M1TJ INSTRUCTION sheet.
The high speed sampling period is suitable for the operation of high speed response.
With a backlight liquid crystal display and the 3 display, can display the current value, the target value, the amount of operation.
1 digital controller can be multi point control / series control / proportion control.
Standard is equipped with a variety of computing functions.
Equipped with DeviceNet communication function.
Data setting and data monitoring can be performed by means of a communication program. Name: HFU with Programless Communications *1.
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: None.
Control outputs 1 and 2: None.
Control outputs 3 and 4: None.
Auxiliary output: Transistor output: 4 points (sinking).
Functions: burnout Heater alarm, None; Event inputs, 4.
Communications functions: Port C: RS-422,
From End Unit: Port A: RS-485.
Input type: No input.
Terminal: M3 terminal.
In-panel Temperature Controller with Flexible,
Modular Design and Wide Integration with Host,
Devices.
The compact modular structure enables construction of temperature,
systems optimally suited to the application.
Connection can be made to a Programmable Controller without any,
programming required, reducing the number of steps required in ladder,
programming design.
One fully universal-input Unit includes a thermocouple, platinum-resistance,
thermometer, and analog input for easy selection and reduced inventory,
requirements.
Connect directly to the G33ZA Multi-channel Power Controller using,
optimum cycle control for high-accuracy regulation with minimal noise E3T-SR44-M1TJ Manual.
Autotuning (AT) can be used for independent heating/cooling PID control.
Self-tuning (ST) can be used to calculaate the PID constants with the step,
response method E3T-SR44-M1TJ Manual.
Up to 16 Temperature Controllers can be connected to a single DeviceNet,
Communications Unit.