Appearance: Shielded, M30.
Sensing distance: 10 mm.
Output configuration : DC 3-wire, NPN.
Operation mode: NO.
Inductive Profoximity Sensor with.
Chemical-resistant Fluororesin Case.
Housing and mounting are made of Fluororesin resistant to chemicals.
Maximum sensing distance: 10 mm. Size: 96 x 96mm E3X-DA41RM-S INSTRUCTION sheet.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: position ratio with relay output E3X-DA41RM-S
Control output 2: position ratio with relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input E3X-DA41RM-S INSTRUCTION sheet.
Communication: RS-422.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors E3X-DA41RM-S INSTRUCTION sheet.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output.
Through the infrared port can be carried out from the front of the communication.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Protective tubing length (mm): M8 screw.
Lead wire length: 1 m.
A Wide Variety of High-precision.
Temperatuure Sensors E3X-DA41RM-S Manual.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Teemperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E3X-DA41RM-S Manual.
Related products
OMRON
Digital Fiber Amplifier Unit
E3X-DAG11-S
OMRON Digital Fiber Amplifier Unit E3X-DAG11-S
Item: Mark-detecting models multiple color l
OMRON
Digital Fiber Amplifier Unit
E3X-DA9R-S
OMRON Digital Fiber Amplifier Unit E3X-DA9R-S
Type: Ultra-long-term APC models. Connecting
OMRON
Digital Fiber Amplifier Unit
E3X-DA8RM-S
OMRON Digital Fiber Amplifier Unit E3X-DA8RM-S
Item: Advanced models External-input models.
OMRON
Digital Fiber Amplifier Unit
E3X-DA11AT-S
OMRON Digital Fiber Amplifier Unit E3X-DA11AT-S
Item: Advanced models ATC function models.