OMRON
Home >> Download >> OMRON >> Manual Download >> E3Z-LT81-D INSTRUCTION sheet ()

E3Z-LT81-D INSTRUCTION sheet ()

Brand: OMRON
Product model: E3Z-LT81-D
Name: photoelectric sensors
Sort: INSTRUCTION sheet
File language: English
File size: 0.96MB
Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function E3Z-LT81-D INSTRUCTION sheet E3Z-LT81-D
Event input points: -.
Transfer output: -.
Communication: RS-232C.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance E3Z-LT81-D INSTRUCTION sheet.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc E3Z-LT81-D INSTRUCTION sheet. , can be a key operation. High performance price ratio standard type proximity sensor.
Standard cable protector.
The new DC two-wire type.
Non polar proximity sensor.
Type: DC two-wire / connector type.
Polarity: there.
Shape: non shield, M8.
Detection range: 4mm.
Action mode: NO. Size: 48 x 48mm.
Control output 1: linear current output.
Control output 2:--.
Auxiliary output: 3 points (common universal).
Power supply voltage: AC100 ~ 240V.
Terminal type: screw terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: RS-485.
Event input: 2 points.
Remote SP input: -.
Transfer output: -.
Using large font PV display (white), improve visibility.
Selection, operation and setting.
Functional performance of input and output points.
Support for more extensive range of applications.
Using high PV 15.2mm display (white), improve visibility.
High speed sampling to achieve 50ms.
With auxiliary output (maximum 3 points), event input (maximum 4 points), the transmission output,
Remote SP input function, support for a varieety of applications E3Z-LT81-D Manual.
E5CC 60mm has a depth of slender body.
The use of communication adapter cable (sold separately) connected with a computer.
After that, no power supply connection can be set.
It can be easily set by CX-Thermmo (sold separately) E3Z-LT81-D Manual.
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication.
Related products