OMRON
Home >> Download >> OMRON >> Manual Download >> E5AN-HTAA2HH01BF-FLK INSTRUCTION Manual ()

E5AN-HTAA2HH01BF-FLK INSTRUCTION Manual ()

Brand: OMRON
Product model: E5AN-HTAA2HH01BF-FLK
Name: digital controller
Sort: INSTRUCTION Manual
File language: English
File size: 0.96MB
Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 1 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use E5AN-HTAA2HH01BF-FLK INSTRUCTION Manual.
Event input points: - E5AN-HTAA2HH01BF-FLK
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV E5AN-HTAA2HH01BF-FLK INSTRUCTION Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc E5AN-HTAA2HH01BF-FLK INSTRUCTION Manual. , can be a key operation. Size: M8, Shielded.
Sensing distance: 2.0 mm.
Connection: Pre-wired.
Body material: Stainless steel.
Thread length (overall length): 27 (40).
Output configuration: NPN.
Operation mode NC.
Safe Mounting with Greater.
Sensing Distance.
Ensures a sensing distance approximately 1.5 to 2,
times larger than that of any conventional OMRON Sensor.
Problems such as the collision of workpieces are eliminated.
Full range of standard sizes (M8, M12, M18 and,
M30; both long and short barrels).
Modular construction simplifies customization. Control output: Relay output.
Auxiliary output: Two.
Communications: --.
Heater burnot: Detection for Single-phase heater.
Event inputs: One.
Power supply voltage: 100 to 240 VAC.
The E5DC-800 Mounts to DIN Track and Is Ideal,
for Connections to HMIs and PLCs.
It provides the Same Easy Operation and,
Advanced Performance as the Rest of the,
E5@C-800 Series.
A slim body at 85 × 22.5 mm (D × W) that fits into narrow control,
panels and mounts to DIN Track.
Removable terminal block for easy replacement to simplify maintenance.
High-sspeed sampling at 50 ms for applications with high-speed,
temperature increases E5AN-HTAA2HH01BF-FLK Manual.
Easy connections to a PLC with programless communications.
Models are available with up to 2 auxiliary outputs and 1 event input to,
commplete basic functions E5AN-HTAA2HH01BF-FLK Manual.
A white PV display (height: 8.5 mm) is easy to read when setting up,
checking alarms, and making settings in a control panel.
Related products
OMRON
Programmed temperature controller
E5AN-HTAA2HB
OMRON Programmed temperature controller E5AN-HTAA2HB
Size: 96 x 96mm. Category: power AC100 240V
OMRON
Programmed temperature controller
E5AN-HTAA2HH03BD-FLK
OMRON Programmed temperature controller E5AN-HTAA2HH03BD-FLK
Size: 96 x 96mm. Type: power AC/DC24V with. S
OMRON
Programmed temperature controller
E5AN-HTAA2HHBFD
OMRON Programmed temperature controller E5AN-HTAA2HHBFD
Size: 96 x 96mm. Type: power AC/DC24V with. S