OMRON
Home >> Download >> OMRON >> Manual Download >> E5CN-C203T-W-FLK USER'S MANUAL ()

E5CN-C203T-W-FLK USER'S MANUAL ()

Brand: OMRON
Product model: E5CN-C203T-W-FLK
Name: Temperature Controller
Sort: USER'S MANUAL
File language: English
File size: 2.75MB
E3F3-D81M detection method: diffuse reflection type,
Wire lead out type,
Type: metal appearance; PNP output,
Threaded cylindrical photoelectric sensor, built-in amplifier,
Photoelectric sensor with proximity sensor appearance
High anti interference with optoelectronic -IC technologyControl output 1: relay output E5CN-C203T-W-FLK USER'S MANUAL.
Control output 2: relay output.
Auxiliary output: 2 points E5CN-C203T-W-FLK
Communication mode: RS-485.
Heater break: 1.
Event input: -.
Power supply voltage: 100 ~ 240VAC.
Resistance to environmental performance of the industry leader.
Sulfide gas, dust, condensation of the corresponding.
Environment specific temperature controller.
Temperature control performance outstanding.
High contrast display screen E5CN-C203T-W-FLK USER'S MANUAL.
Set simple, easy to operate. No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: Transfer output using control output.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance E5CN-C203T-W-FLK USER'S MANUAL. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible wwith Support Software (CX-Thermo version 4 E5CN-C203T-W-FLK MANUAL. 2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. Size: M8(Stainless steel)(See note 2.); Double; Unshielded.
Sensing distance: 4 mm.
Connnecting method (See note 1 E5CN-C203T-W-FLK MANUAL. ): Pre-wired.
Body length: Long.
Output configuration: NPN.
Operation mode NO.
A new generation in global applications.
Related products
OMRON
Foundation type temperature controller
E5CN-C203T-W-FLK
OMRON Foundation type temperature controller E5CN-C203T-W-FLK
The main ody: terminal type, temperature inp
OMRON
Foundation type temperature controller
E5CN-R2H03T-W-FLK
OMRON Foundation type temperature controller E5CN-R2H03T-W-FLK
The main ody: terminal type, temperature inp
OMRON
Foundation type temperature controller
E5AN-Q3H03T-W-FLK-N
OMRON Foundation type temperature controller E5AN-Q3H03T-W-FLK-N
Size: 96 x 96mm. Ontology: terminal type, tem
OMRON
Foundation type temperature controller
E5EN-Q3H03T-W-FLK-N
OMRON Foundation type temperature controller E5EN-Q3H03T-W-FLK-N
Size: 48 x 96mm. Ontology: terminal type, tem