A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Temperature range: 30 to 110.
Positive / inverse action: anti movement (heating).
Adjustment mode: OFF, ON action.
With the aid of microcomputer, the temperature control can be realized with high precision (0.1 degrees C).
Combined use of control equipment, adjustable sensitivity.
Attached to facilitate the energy saving operation of the set value conversion function, as well as ease of operation to stop the control function E5CN-C203T-W-FLK
E5CN-C203T-W-FLK Size: 48 * 48mm, terminal type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: -.
Event entry point: 2 E5CN-C203T-W-FLK.
Transfer output: output (using control output).
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms E5CN-C203T-W-FLK.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can perform flexible contact output.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Size: DIN 1/16, 48 X 48 x 60mm E5CN-C203T-W-FLK.
Power supply voltage: AC100 ~ 240V.
Input type: thermocouple.
Alarm points: 1 points.
Control output: relay output.
Simple new temperature controller, easy to achieve temperature control.
Good visibility (character height EE5CSL:21 E5CN-C203T-W-FLK. 7mm, E5CWL:16.2mm (PV), E5EWL:20mm (PV)).
From the front panel depth: 60mm.
Parameter is less, set simple.
Sampling time was reduced to 250ms.