E32-D24 type: standard type; standard,
Features: with 2 cylinder side (small),
Bending radius (mm): R10.
Standard test object (minimum test object) (mm) 1: (0.005),
Fiber element for meeting diversified needsTerminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 4.8 dia.
Protective tubing length L: 20 cm E5CN-HC2BD INSTRUCTION Manual.
Lead wire type: Heat resistive.
Lead wire length M: 4m
E5CN-HC2BD
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E5CN-HC2BD INSTRUCTION Manual. Element type: K (CA).
Terminal type: Exposed-terminal Models.
Protective tubing diameter D (mm): 4.8 dia.
Protective tubing length L: 35 cm.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E5CN-HC2BD INSTRUCTION Manual.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Temperature range: 0°C to 100°C.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 96 × 96 mm.
Control type: Basic control (1 loop).
Control mode: Single-loop standard control Single-loop heating and cooling control.
Outputs(control/transfer): 2 points: Current and Current.
Optional functions: Auxiliary outputs (SUB), 4;
Event inputs, 2; Serial communications, No.
E5AR Digital Controllers offer high speed,
high precision, and multiple I/O and use a 5-digit,
3-row LCD display for high visual clarity.
A short sampling period of 50 ms enables use in applications,
requiring high-speed response.
PV, SP, and MV data is displayed simultaneously in a 3-row,
negative LCD display with a backlight.
Multiloop control, cascade control, and proportional control are,
possible with a single Controller.
When using models with CompoWay/F communications, initial,
settings can be downloaded and settings can be masked using,
Support Software (CX-Thermo version 4 E5CN-HC2BD Manual. 0 or higher).
Equipped with calculation functions as a standard (e.g., square,
root calculation and broken-line approximation) E5CN-HC2BD Manual.
DeviceNet Communications.
Data setting and monitoring can be performed without special programming.