Sensing method: Diffuse-reflective.
Appearance: Vertical.
Connection method: Pre-wired Connector (M12).
Sensing distance: 2m.
Water- and Oil-resistant.
Photoelectric Sensor with.
Metal Housing Used for Long.
range Sensing.
Excellent resistance against the water and oil.
Easy application in locations with oil mist E5ER-PRTDF INSTRUCTION Manual.
Long-range sensing up to 30 m with Through-beam models
E5ER-PRTDF
Shock resistance rated at 1,000m/s2.
Product lineup includes metal M12 pre-wired connector models.
NPN/PNP selector switch output. Size: M12 (Brass); Single; Shielded.
Sensing distance: 10 mm.
Connecting method (See note 1.): M12 Connector.
Body length: Long.
Output configuration: PNP.
Operation mode NC.
A new generation in global applications E5ER-PRTDF INSTRUCTION Manual. Size: 48 x 48mm.
Control output 1: linear current output.
Control output 2:--.
Auxiliary output: 2 independent points.
Power supply voltage: AC100 ~ 240V.
Terminal type: screw terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: -.
Event input: 2 points.
Remote SP input: there E5ER-PRTDF INSTRUCTION Manual.
Transfer output: -.
Using large font PV display (white), improve visibility.
Selection, operation and setting.
Functional performance of input and output points.
Support for more extensive range of applications.
Using high PV 15.2mm display (white), improve visibility.
High speed sampling to achieve 50ms.
With auxiliary output (maximum 3 points), event input (maximum 4 points), the transmission output,
Remote SP input function, support for a variety of applications.
E5CC 60mm has a depth of slender body.
The use of communication adapter cable (sold separately) connected with a computer.
After that, no power supply connection can be set.
It can be easily set by CX-Thermo (sold separately).
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication. Case color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-485.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of tthe Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E5ER-PRTDF Manual.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E5ER-PRTDF Manual.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.