Control output 1: Linear current output.
Control output 2: --.
Auxiliary output: Three.
Communications: --.
Heater burnout: --.
Event inputs: --.
Power supply voltage: 24 VAC/VDC.
Large White PV Display That’s Easier to Read.
Easy to Use, from Model Selection to Setup and Operation.
A Complete Range of I/O Capacities,
Functions, and Performance EE-SX670-WR INSTRUCTION sheet.
Handles More Applications
EE-SX670-WR
The white PV display with a height of 15.2 mm improves visibility.
High-speed sampling at 50 ms.
Short body with depth of only 60 mm.
Easy connections to a PLC with programless communications.
Use component communications to link Temperature,
Controllers to each other. Type: 3 wire, shielded.
Shape: 5.4.
Detection range: 1mm EE-SX670-WR INSTRUCTION sheet.
Connection mode: lead type (2m).
Wire specification: PVC (oil resistant).
Action mode NC.
NPN output.
Proximity sensors for preferred world top performance and quality.
Standard type of magnetic metal detection.
Rich variety.
According to the conditions to choose the most suitable models.
Anti interference function of different frequency range models.
Has excellent environmental performance EE-SX670-WR INSTRUCTION sheet.
Standard wire material for oil resistant PVC.
Test face using cutting oil material.
Standard wire jacket. Sensor type: BGS (background suppression).
Sensing distance: 100 mm.
Connection method: M12 connector.
Model: PNP output.
A new generation in sensing performance.
Simplicity.
Simple selection.
Simple installation.
One family for all.
All standard applications covered.
A wide variety of models.
Models designed for special applications.
Non-stop detection.
High quality and reliability.
High EMC protection.
High light immunity.
Robust and waterproof housing. Size: 48 x 96mm.
Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2.
Transfer output: output (using control output).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV EE-SX670-WR Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation EE-SX670-WR Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.