OMRON
Home >> Download >> OMRON >> Manual Download >> H5CN-XZNS INSTRUCTION MANUAL ()

H5CN-XZNS INSTRUCTION MANUAL ()

Brand: OMRON
Product model: H5CN-XZNS
Name: digital timer
Sort: INSTRUCTION MANUAL
File language: English
File size: 1.10MB
Supply voltage: 12 VDC.
Control output: Contact output, SPDT (time-limit SPDT).
Eight-mode Timer.
Multiple time ranges and operating modes let you cover a wide,
range of applications.
The time-limit DPDT output contacts can be changed to time-limit,
SPDT and instantaneous SPDT output contacts using a switch H5CN-XZNS INSTRUCTION MANUAL.
Sequence checks are easily performed by setting an instanta,
neous output to 0 H5CN-XZNS
Start signal control for the H3DK-M. Operating modes: Flicker OFF start.
Supply voltage: 100 to 240 VAC/100 to 125 VDC, 24 to 48 VAC/12 to 48 VDC.
0.05 s to 300 h models: 11-pin models.
DIN 48 × 48-mm Twin Timers.
Wide power supply ranges of High Voltage 100 to 240 VAC/100,
to 125 VDC and Low Voltage 24 to 48 VAC/12 to 48 VDC H5CN-XZNS INSTRUCTION MANUAL.
ON- and OFF-times can be set independently and so,
combinations of long ON- or OFF-time and short OFF- or ON,
time settings are possible.
Twenty-four time ranges from 0.05 s to 300 h depending on the,
model to be used.
Models with a flicker ON start or flicker OFF start are available.
Easy sequence checks through instantaneous outputs for a,
zero set value at any time range H5CN-XZNS INSTRUCTION MANUAL.
Length, when panel-mounted with a Socket, of 80 mm or less.
11-pin and 8-pin models are available. Operating modes: Power OFF Delay.
Supply voltage: 24 to 48 VAC/DC.
Control output: Contact output: SPDT.
H3DK-H: S Series (time range: 0.1 to 12 s).
Set two time ranges with each Timer, from 0.1 to 12 seconds for,
the S Series and from 1.0 to 120 seconds for the L Series. Type: H5CX-L series.
Time specifications: 0.001 to 9.999 s, 0.01 to 99.99 s,
0.1 to 999.9 s, 1 to 9999 s, 1 s to 99 min 59 s, 0.1 to 999.9 min,
1 to 9999 min, 1 min to 99 h 59 min, 0.1 to 999.9 h, 1 to 9999 h.
Operating modes: Timer Mode, A: Signal ON Delay I, A-1: Signal ON Delay II,
A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat cycle 1,
b-1: Repeat cycle 2, d: Signal OFF Delay, E: Interval, F: Cumulative,

Z: ON/OFF-duty-adjustable flicker, S: Stopwatch, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1,
toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2 H5CN-XZNS Manual.
External connections: 8-pin socket.
Input: Signal, Reeset (NPN input) H5CN-XZNS Manual.
Output: Contact output (time-limit SPDT).
Supply voltage: 12 to 24 VDC/24 VAC.
The Timer with the Shortest Body,
in the Industry.
Related products
OMRON
Digital Timer
H5CN-XANM
OMRON Digital Timer H5CN-XANM
Display type: UP display timer increments fo
OMRON
Digital Timer
H5CN-XBNM
OMRON Digital Timer H5CN-XBNM
Display type: UP display timer increments fo
OMRON
Digital Timer
H5CN-XZNS
OMRON Digital Timer H5CN-XZNS
Display type: UP display timer increments fr
OMRON
Digital Timer
H5CN-XCNM
OMRON Digital Timer H5CN-XCNM
Display type: UP display timer increments fo