CPU Unit: CP1L-L CPU Units with 20 Points.
Specifications: CPU type, Memory capacity: 5K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, AC power supply; Output method, Relay output;
Inputs, 12; Output, 8.
Standards: UC1, N, L, CE CJ1W-AD042 PDF datasheet.
High Performing Programmable Controller with Embedded Ethernet
CJ1W-AD042
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port.
"CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams. CPU Unit: CP1L-M CPU Units with 30 Points.
Specifications: CPU type, Memory capacity: 10K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, DC power supply; Output method, Transistor output (sourcing);
Inputs, 18; Output, 12 CJ1W-AD042 PDF datasheet.
Standards: UC1, N, L, CE.
High Performing Programmable Controller with Embedded Ethernet.
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port.
"CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port CJ1W-AD042 PDF datasheet.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams. Unit type: CJ1 CPU Bus Unit.
Product Name: FL-net Unit.
Specifications:Communications interface,
100Base-TX; Communications functions,
With FL-net Ver. 2.0 specifications,
(OPCN-2) Data links and message service,
Max. Units mountable per CPU Units, 4.
No. of unit numbers allocated: 1.
Current consumption : 5V, 0.37A; 24V,--.
Standards: UC1, CE.
Connect to Multivendor Controller Networks.
This Unit allows you to connect to FL-net,
an open network based on Ethernet.
Multivendor FL-net networks can be built,
to combine CJ series PLCs with CNC machines,
robots, and PLCs from other manufacturers. Unit type: CJ1 Special I/O Units.
Product name: Analog Input Unit.
I/O points: 4 inputs;
Signal range selection: 1 to 5 V, 0 to 5 V,
0 to 10 V, -10 to 10 V, 4 to 20mA;
1/4,000(Settable to 1/8,000)*2 .
Conversion period: 1 ms/point,
(250 μs/point can also be set.)*2.
Accuracy at ambient temperature of 25°C:
Voltage: ±0.2% of F. S. Current: ±0.4% of F.S.
External connection:: Removable terminal block CJ1W-AD042 PDF catalog.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.42A; 24V, --.
Standards: UC1, N, L, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup.
Anaalog Input Units for converting analog input,
signals into binary data CJ1W-AD042 PDF catalog.
Analog Output Units for converting binary ,
data into analog output signals.