Model: C500-BC081(3G2A5-BC081).
8 slots(3 linkable slots).
Unit type: CJ1 Basic I/O Units.
name: B7A Interface Units.
Specifications: I/O points, 32 inputs/outputs;
External connection, Removable terminal block.
No. of words allocated: 4 words.
Current consumption: 5V, 0.07A; 24V, --.
Standards: UC1, CE CJ1W-MCH71 PDF datasheet.
It transmits 16 points of I/O signals per,
word with a pair of cables
CJ1W-MCH71
Easy and minimized wiring effort,
The B7A Interface Unit and B7A Link Terminal,
can be used in the same way as a standard,
Basic I/O Unit and I/O Terminal without,
any need to worry about communications.
This characteristic reduces the wiring,
when using more than one relatively remote,
sensor or actuator CJ1W-MCH71 PDF datasheet.
ASCII Unit
This program runs independently from the ladder-diagram program in the PLC.
Name: ASCII Module.
Model: C200H-ASC21.
Communications port>Port 1: RS-232C(peripheral device or termi-nal connection).
Communications port>Port 2: RS-422A/485(peripheral I/O Cable (for Rack I/O to Backplane) 0.6 m (L) CV500-CN613Unit type: CS1 Basic I/O Units.
Product name: B7A Interface Unit CJ1W-MCH71 PDF datasheet.
Specifications: 32 inputs/outputs.
Mountable Racks: CPU Rack, CS1W-BC,
@@3, Yes, @@2, Yes;
C200HX/HG/HE Expansion I/O Rack, No.
CS1 Expansion Rack, CS1W-BI,
@@3, Yes, @@2, Yes;
CS1 Long distance Expansion Rack, Yes;
SYSMAC BUS Slave Rack, No.
Words required: 2 input words and 2 output words.
Current consumption: 5V system, 0.09A;
26 V system, --.
Standards: UC1, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control. Specification: Thermocouple input (K, J, L, T, R, S, B),
ON/OFF or advanced PID control,
manual op-eration,
transistor (PNP) output, 4 loops.Unit type: CJ1 CPU Bus Unit.
Product Name: Controller Link Unit.
Specifications:Communications cable,
Wired shielded wisted-pair cable ;
Communications type,
Data links and message service;
Duplex support, No;
Max. Units mountable per CPU Unit, 8;
No. of unit numbers allocated: 1.
Current consumption : 5V, 0.35A; 24V,--.
Standards: UC1, N, L, CE.
New Controller Link Units,
Now with 4,000 Send Words.
The Controller Link is an FA,
network that can send and receive,
large amounnts of data easily,
and at high speed CJ1W-MCH71 PDF catalog.
The Controller Link supports data,
links that enable sharing,
data between PLCs and computers,
and a message service that enables,
sending and receiving data whenever required.
Systtems can be flexibly built by using Repeater,
Units to enable T-branches, long-distance wiring,
and converting part of the network to optical cable CJ1W-MCH71 PDF catalog.