CV500-FH SYSMAC BUS PC Unit Floppy/Hard Disk Drive For 200 VAC CV500-FHD02-E.Output method: Transistor sourcing.
Inputs: ---.
Outputs: 8.Model: C200HW-ME16K.
Capacity: 16K words.CV500-MP SYSMAC BUS PC Unit PC Card Interface Board For PCMCIA 2.1 Type I and II cards CV500-MP602.C200H-CPU01-E/C200H-CPU03-E CPUs
High Spec, Small Rack Style, OEM Version
The C200H-CPU01-E and C200H-CPU03-E controllers offer big machine functions
in a system designed ideally for basic OEM systems from 50 to 480 I/O CP1E-N40S1DT-D PDF datasheet
CP1E-N40S1DT-D A wide
variety of plug-in style I/O modules are available, including intelligent modules.Unit classification: CJ1 CPU Bus Unit.
Product name: EtherNet/IP Unit.
Specifications:Communications cable,
Shielded twisted-pair STP),
cable Categories: 100 Ω at 5,5e;
Communications functions, Tag Data Link,
Functions, Message Communications Functions;
Units per CPU Unit, 8 max CP1E-N40S1DT-D PDF datasheet.
No. of unit numbers allocated: 1.
Current consumption: 5V system, 0.41A;
24V system, --.
Standards: UC1, N, L, CE.
Introducing the New EtherNet/IP Unit.
More Than 180,000 Words of Tag,
Data Link Capacity!
EtherNet/IP is an industrial multivendor,
network that uses Ethernet CP1E-N40S1DT-D PDF datasheet.
Managed by the ODVA (Open DeviceNet Vendors,
Association), it has open standards and is,
used with a wide range of industrial devices.
The EtherNet/IP Unit supports tag data links,
to enable sharing data between devices at,
Ethernet nodes and a message service for,
sending and receiving data when required.
The EtherNet/IP Unit supports the same,
FINS/UDP and FINS/TCP functionality,
as Ethernet Units.
Model : C500-PS211.
24 VDC.
Output ratings: 7 A, 5 VDC.Unit type: CS1 Special I/O Units.
Product name: Analog Input Unit (100 mV).
Input points : 8 inputs.
Signal range: 0 to 100 mV, ±100 mV.
Conversion speed (resolution):
200ms/8 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.08A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compaared,
with previous systems CP1E-N40S1DT-D PDF catalog.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CP1E-N40S1DT-D PDF catalog.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.