C1000H-SL SYSMAC BUS SYSMAC LINK C1000H-SLK11.CV500-CN Cable Motion Control Connecting Cables 4 m CV500-CN4244 platinum resistance thermometer inputsModel: C500-COV03.
C500 I / O Control Unit, I / O Interface For unitC500-DA Special I/O Unit Analog Output C500-DA103.
Output: 4 pts.
Specification: -10~+10V CRT1-AD04 PDF datasheet. Model: C200H-BC051-V2.
No. of I/O slots: 5 slots.8 pts, 1 A, 120 VAC
CRT1-AD04Name: e-CON Connectors.
Specifications: Inputs/Outputs;
8 inputs /8 outputs; PNP;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system CRT1-AD04 PDF datasheet.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Number of I/O points: 128 inputs and 128 outputs.C200HW Communications Interface Module C200HW-PRT21Peripheral port to RS-422 conversion cable (length: 0 CRT1-AD04 PDF datasheet. 2 m).Size: 35mm.
Type: 4 lines.
Lighting voltage: DC24V.
Color: blue.
Large tactile buttons and uniform lighting to create a general space.
Backlight brings a uniform, elegant and pleasant lighting.
Large tactile buttons are easier to touch.
Drive rod mechanism to keep the direction of the parallel button, even if the pressure on the side of the.
Damping mechanism to ensure high impact resistance.
A slim body with a thickness of 14.6 mm. Unit type: CS1 Special I/O Units.
Product name: Isolated-type DC Input Unit.
Input points : 4 inputs.
Signal range: 4 to 20 mA, 0 to 20 mA,
0 to 10 V, ±10 V, 0 to 5 V, ±5 V,
1 to 5 V, 0 to 1.25 V, ±1.25 V.
Conversion speed (resolution):
20 ms/4 inputs, 10 ms/2 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 26V, 0.12A.
Standards: UC1, N, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems CRT1-AD04 PDF catalog.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CRT1-AD04 PDF catalog.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.