Model : C500-LDP01-V1.
Has 40 instructions (same as a C20P.) Input and output points (16 each.).Supply voltage: 100 to 120 or 200 to 240 VAC, 50/60 Hz
Output capacity: DC5V, 6.5ASpecifications: 8 Kwords with clock.Unit type: CS1 Special I/O Units.
Product name: Isolated-type Resistance,
Thermometer Input Units (Ni508 CRT1-OD16TAH PDF datasheet. 4 Ω).
points Input: 4 inputs.
Signal range selection:
Set separately for each input
CRT1-OD16TAH
I/O type: INi508.4.
Conversion speed (resolution):
100 ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.15A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices CRT1-OD16TAH PDF datasheet.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them CRT1-OD16TAH PDF datasheet.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools. Model: C200H-IM212.
No. of inputs: 16 pts.
Input voltage: 24 VAC/DC, +10%/–15%.
Input current: 7mA, 24VDC.
Isolation: Photo-coupler.
Indica-tor: LED.
External connec-tions: Remove-able termi-nal blocks.
Inputs percom-mon: 16 pts.
Internal currentcon-sump-tion: 10mA Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Thermocouple Input Units.
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: B, E, J, K, L, N, R, S,
T, U, WRe5-26, PLII, ±100 mV.
Conversion speed: 20 ms/4 inputs,
10 ms/2 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 26V, 0.08A.
Standards: UC1, N, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space commpared,
with previous systems CRT1-OD16TAH PDF catalog.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CRT1-OD16TAH PDF catalog.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.