Includes a Fuzzy Training System Manual,
a Main Unit, a C200H-MR831 Memory Unit,
a C200H-PRO27-E Programming Console,
a C200H-CN222 Cable for the Programming Console,
C500-SU981-E Fuzzy Training Software,
an RS-232C Cable, and a carrying belt.Name: e-CON Connectors.
Specifications: Outputs; 16 outputs; NPN;
Without Short-circuit and,
Disconnected Line Detection CS1W-BC083 PDF datasheet
CS1W-BC083
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site CS1W-BC083 PDF datasheet.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. UM: 15.2K words.
DM: 6K words.
EM: 6K words.
Instruction processing time (basic instructions): 0.15 µ.s min.
No. of I/O points: 1, 184 points.
Max. no.of con-necting Expansion I/O Racks: 3 Racks CS1W-BC083 PDF datasheet.
Max. no. of connecting High-density I/O Units(i.e., Group-2): Unavailable.
Max. no. of con-necting Special I/O Units: 10.
RS-232C: NO.C200H Discrete I/O Data Access Console C200H-DAC01Model : C500-LK203.
RS-232C/RS-422.Number of analog inputs: 4 inputs.
Number of analog outputs: 2 outputs.
Input signal ranges: –10 to 10 V, 0 to 10 V, 0 to 5 V.
Output signal ranges: –10 to 10 V.Model: C200H-OD216.
No. of points: 8 pts.
Specifications: 0.8 A, 24 VDC. source type (PNP). with load short protection.Unit classification: CJ1 Special I/O Units.
Product name: Process Analog Input Units,
(Isolated-type Resistance Thermometer Input Units).
Input points: 4 inputs.
Signal range selection: Common inputs.
Signal range: Resistance thermometer: Pt100, JPt100.
Conversion speed (resolution): Conversion,
speed: 250 ms/4 inputs.
Accuracy at ambient temperature of 25°C:
Accuracy: (±0.3% of PV or ±0.8°C,
whichever is larger) ±1 digit max.
External connection: Removable terminal block.
No. of unit numbers allocated: 1.
Curreent consumption: 5V, 0 CS1W-BC083 PDF catalog. 25A; 24V, --.
Standards: UC1, CE.
A Single Unit Handling All Types of Inputs,
such as Temperature Sensor Inputs and,
Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5V).
A Unit supports four inputt channels,
each of which can be set to a
platinum resistance thermometer, thermocouple,
and DC signal (current, voltage) CS1W-BC083 PDF catalog.