Actuator: Plunger.
Conduit openings: G1/2 (PF1/2).
1NC/1NO (Slow-action).
Robust safety limit switch with metal housing.
Slow-action and snap-action contact with,
certified direct opening operation certification.
Direct opening mechanism (NC contacts only) added to,
enable opening contacts when faults occur, such as fused contacts D4A-4501N PDF datasheet.
Safety of lever settings ensured using a mechanism that,
engages a gear between the operating position indicator plate and the lever
D4A-4501N
Equipped with a mechanism that indicates the applicable,
operating zone, as well as push-button switching to control left and right motion.
Head seal structure strengthened to improve seal properties.
(TÜV: IEC IP67, UL: NEMA 3, 4, 4X, 6P, and 13) D4A-4501N PDF datasheet.
Wide standard operating temperature range: –40 to 80°C (standard type).
Certified standards: UL, CSA, EN (TÜV), and CCC.
Operation indicator: Without operating indication; Standard load.
Ratings: 5 A at 250 VAC; 4 A at 30 VDC.
Actuator: Roller lever.
Cable length : 5m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard) D4A-4501N PDF datasheet.
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.) Ratings: 1 A at 30 VDC.
LED indicator: With indicator.
Actuator: Sealed crossroller plunger.
Many Models Including Roller Lever.
Switches are Only 16-mm Thick with Connector.
New center roller lever moddels that enable ganged mounting D4A-4501N PDF catalog.
of up to 6 Switches.
Cable connectors for easy Switch replacement.
Triple-seal construction to provide IEC IP67 degree of protection.
Operation indicators available for easy monitoring,
((standard indicator is lit when Switch is not operating) D4A-4501N PDF catalog.
Approved by UL and CSA.
(Ask your OMRON representative for Information on approved models.)