Brand: OMRON
Product model: D4E-2H20N
Name: Small closed limit switch
Sort: PDF datasheet
File language: English
File size: 1.70MB
Ratings: Standard load; 5 A at 125 VAC.
Cable: VCTF cable *2.
Actuator: Roller lever.
Cable length : 5 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection D4E-2H20N PDF datasheet.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material D4E-2H20N
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers D4E-2H20N PDF datasheet.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Actuator: Adjustable roller lever, form lock (metal lever, resin roller).
Conduit size: 2-conduit; G1/2.
Built-in switch mechanism: 2NC/1NO MBB (Slow-action) D4E-2H20N PDF datasheet.
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Type: Welding / wire type, with right column.
Drive rod: needle shaped button type.
Terminal specifications: with wire, under the lead.
Contact specificationns: 1b D4E-2H20N PDF catalog.
The minimum size of the long stroke type can be reliably switch
The body part size is 78% of the previous generation product, which is beneficial to the miniaturization of the equipment.
No swing bars are also used ffor easy long stroke specifications (OT reference value: 1 D4E-2H20N PDF catalog. 4mm).
Without harmful substances to the environment, the lead type has also been lead-free.
Related products
OMRON
Small closed limit switch
D4E-2D21N
OMRON Small closed limit switch D4E-2D21N
Type: screw terminal type, micro load with ca
OMRON
Small closed limit switch
D4E-1E20N
OMRON Small closed limit switch D4E-1E20N
Type: screw terminal type, general type witho
OMRON
Small closed limit switch
D4E-2E21N
OMRON Small closed limit switch D4E-2E21N
Type: screw terminal type, micro load with ca
OMRON
Small closed limit switch
D4E-2C20N
OMRON Small closed limit switch D4E-2C20N
Type: screw terminal type, small load without