Brand: OMRON
Product model: D4SL-N4NFA-DN
Name: Guard Lock Safety-door Switch/D4SL-N-mounting Slide Key
Sort: PDF datasheet
File language: English
File size: 6.12MB
Type: Welding / wire type, with left column.
Driving rod: R type swing lever type.
Terminal specifications: with wire, under the lead.
Contact specifications: 1c.
The minimum size of the long stroke type can be reliably switch
The body part size is 78% of the previous generation product, which is beneficial to the miniaturization of the equipment D4SL-N4NFA-DN PDF datasheet.
No swing bars are also used for easy long stroke specifications (OT reference value: 1 D4SL-N4NFA-DN4mm).
Without harmful substances to the environment, the lead type has also been lead-free. Operation indicator: Without operating indication; Microload.
Ratings: 0.1 A at 125 VAC; 0.1 A at 30 VDC.
Actuator: Adjustable rod lever.
Cable length : 3m.
Compact Limit Switch That''s Also D4SL-N4NFA-DN PDF datasheet.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material D4SL-N4NFA-DN PDF datasheet.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.) Release key type: Special release key.
Indicator: Orange.
Lock and release types: Mechanical lock Solenoid release.
Contact configuration(door open/closed detection switch,
and lock monitor switch contacts): 3NC+2NC/1NO.
Conduit opening: M20.
Holding Force of 3,000 N.
Two safety circuits and two moonitor contacts provide an,
array of monitoring patterns D4SL-N4NFA-DN PDF catalog.
Standard gold-clad contacts enable use with ordinary loads,
and microloads.
Models with trapped keys prevent workers from being locked,
in hazardous work areas. D4SL-N4NFA-DN PDF catalog.
Models with rear release buttons allow people to unlock the,
Switch and escape if they are locked into hazardous areas.
IP67 degree of protection.