Appearance: Standard.
Sensing method: Through-beam type (with slot).
Cable length: 2 m.
Sensing distance: 5 mm (slot width).
configuration Output: Dark-ON.
Indicator mode: Incident light.
Model: PNP output.
Slim, Compact Photomicrosensor.
that is still easy to use.
Compact, thin profile enables dense mounting E2E-X2D2-N-Z 2M PDF datasheet.
Indicator is visible from both sides.
Wide operating voltage range: 5 to 24 VDC
E2E-X2D2-N-Z 2M Type: plug - in.
Size: 48 x 96mm.
Control output: linear current output.
Auxiliary output: 2 points.
Communication: -.
Heater disconnection: -.
Event input: -.
Power supply voltage: AC100 ~ 240V.
Using large font PV display (white), improve visibility.
Selection, setting and operation more simple and more group of input / output,
Functional performance is stronger, the function is more perfect and more extensive range of applications E2E-X2D2-N-Z 2M PDF datasheet.
E5EC-800 white LCD-PV display height is about 18mm,
The E5AC-800 white LCD-PV display height is about 25mm improved visibility.
The main body is short, the thickness is only 60mm.
50ms high speed sampling period.
A new type of proportional control allows you to control the valve E2E-X2D2-N-Z 2M PDF datasheet. Name: Basic Unit (temperature control) *1.
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: 2.
Control outputs 1 and 2: Current output: 2 points.
Control outputs 3 and 4: Transistor output: 2 points (sinking).
Auxiliary output: None.
Functions: burnout Heater alarm, None; Event inputs, 2.
Communications functions: G3ZA connection port: RS-485,
From End Unit: Port A or port B: RS-485.
Input type: Thermocouple, platinum resistance thermometer,
analog voltage, and analog current selectable for each channel.
Terminal: Screw-less clamp.
In-panel Temperature Controller with Flexible,
Modular Design and Wide Integration with Host,
Devices.
The compact modular structure enables construction of temperature,
systems optimally suited to the application.
Connection can be made to a Programmable Controller without any,
programming required, reducing the number of steps required in ladder,
programming design.
One fully universal-input Unit includes a thermocouple, platinum-resistance,
thermometer, and analog input for easy selection and reduced inventory,
requirements.
Connect directly to the G3ZA Mullti-channel Power Controller using,
optimum cycle control for high-accuracy regulation with minimal noise E2E-X2D2-N-Z 2M PDF catalog.
Autotuning (AT) can be used for independent heating/cooling PID control.
Self-tuning (ST) can be used to calcullate the PID constants with the step,
response method E2E-X2D2-N-Z 2M PDF catalog.
Up to 16 Temperature Controllers can be connected to a single DeviceNet,
Communications Unit.