Ontology: terminal type, analog input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use E2V-X4C1-M1 PDF datasheet.
Event input points: -.
Transfer output: -.
Communication: -
E2V-X4C1-M1
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E2V-X4C1-M1 PDF datasheet.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. High performance price ratio standard type proximity sensor.
Standard cable protector.
The new DC two-wire type.
Non polar proximity sensor.
Type: DC / wire type E2V-X4C1-M1 PDF datasheet.
Polarity: none.
Shape: shield, M30.
Detection range: 10mm.
Action mode: NO. Appearance: U-shaped.
Sensing method: Through beam (with slot).
Sensing distance: 5 mm (slot width).
Output configuration: Light-ON Dark-ON (2 outputs).
Connection method (Cable length): Pre-wired model with robot cable (1 m).
Output type: NPN.
Meeting Customer Needs with.
Ultra-compact Sensors that Mount.
with M3 Screws.
Mount using M3 or M2 screws.
Reliable sensing slot depth of 6.5 mm.
Indication of sensing window for easy confirmation of,
insertion depth.
Bright indicator for confirmation from many directions.
Both light-ON and dark-ON outputs provided.
All models available with either standard cable or,
flexible robot cable.
Load short-circuit protection circuit provided. Size: 48 x 48mm.
Control output 1: voltage output (SSR driver).
Control output 2:--.
Auxiliary output: 3 points (common universal).
Power supply voltage: AC100 ~ 240V.
Terminal type: screw terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: 2 point (three phase heater).
Communication: RS-485.
Event input: -.
Remote SP input: -.
Transfer output: -.
Using large font PV display (white), improve visibility.
Selection, operation and setting.
Functional performance of input and output points.
Support for more extensive range of applications.
Using high PV 15.2mm display (white), improve visibility.
High speed sampling to achieve 50ms.
With auxiliary output (maximum 3 points), event input (maximum 4 points), the transmission output,
Remote SP input function, support for a variety of applications E2V-X4C1-M1 PDF catalog.
E5CC 60mm has a depth of slender body.
The use of communication adapter cable (sold separately) connected with a computer.
After that, no power supply connection can be set.
It can be easily set by CX-Thermmo (sold separately) E2V-X4C1-M1 PDF catalog.
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication.