Size: M18 (brass), single distance, non shield type.
Detection range: 10mm.
Connection mode: lead type (cable length is 2M and 5m two).
Thread length: Standard type.
Output type: PNP.
Action mode NC.
Set up the new standard of the world economy proximity sensor.
OMRON as a pioneer and leader in proximity sensor industry,
Now bring you a new E2B proximity sensor with high performance to price ratio E39-L41 PDF datasheet
E39-L41
This series of products are complete,
Aimed at reasonable prices to meet customer demand for high quality and high reliability of the sensor.
We have tested the product not only on the protection level (IP67) specific item,
The oil spray test was carried out on the condition of the work site.
Simulation test was carried out in the environment of high oil mist concentration E39-L41 PDF datasheet. Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 3.2 dia.
Protective tubing length L: 20 cm.
Lead wire type: Standard.
Lead wire length M: 8m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E39-L41 PDF datasheet.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent:
Detection for single-phase heaters.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of thee Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E39-L41 PDF catalog.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E39-L41 PDF catalog.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.