Type: 3 wire, shielded.
Shape: 5.4.
Detection range: 1mm.
Connection mode: lead type (2m).
Wire specification: PVC (oil resistant).
Action mode NC.
PNP output.
Proximity sensors for preferred world top performance and quality.
Standard type of magnetic metal detection.
Rich variety.
According to the conditions to choose the most suitable models E39-S61 PDF datasheet.
Anti interference function of different frequency range models
E39-S61
Has excellent environmental performance.
Standard wire material for oil resistant PVC.
Test face using cutting oil material.
Standard wire jacket. Size: 96 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode E39-S61 PDF datasheet.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved E39-S61 PDF datasheet.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output.
Through the infrared port can be carried out from the front of the communication.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Element type: K (CA).
Terminal type: Exposed-terminal Models.
Protective tubing diameter D (mm): 4.8 dia.
Protective tubing length L: 50 cm.
A Wide Variety of High-precision.
Temperatuure Sensors E39-S61 PDF catalog.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Teemperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E39-S61 PDF catalog.