Sensor type: BGS (background suppression).
Sensing distance: 100 mm.
Connection method: pre-wired.
Model: PNP output.
A new generation in sensing performance.
Simplicity.
Simple selection.
Simple installation.
One family for all.
All standard applications covered.
A wide variety of models.
Models designed for special applications E52-CA20AY D=1.6 1M PDF datasheet.
Non-stop detection.
High quality and reliability
E52-CA20AY D=1.6 1M
High EMC protection.
High light immunity.
Robust and waterproof housing. Size: 96 x 96mm.
Control output 1: relay output.
Control output 2: relay output.
Auxiliary output: 2 independent points.
Power supply voltage: AC/DC24V.
Terminal shape: screw terminal table type.
Input category: full range multi input E52-CA20AY D=1.6 1M PDF datasheet.
Heating wire break, SSR fault detection function: 2 point (three phase heater).
Communication: RS-485.
Event input: 2 points.
Remote SP input: -.
Transfer output: -.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm E52-CA20AY D=1.6 1M PDF datasheet.
The upper panel and the front panel are equipped with tool ports.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP input, suitable for a wide range of applications.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperature controller is connected to each other by using the component communication.
A new type of proportional control allows you to control the valve. Control output 1: Voltage output.
Auxiliary output: Two.
Communications: RS-485.
Heater burnout: One.
Event inputs: --.
Power supply voltage: 100 to 240 VAC.
Large White PV Display That’s Easier to Read.
Easy to Use, from Model Selection to,
Setup and Operation.
A Complete Range of I/O Capacities,
Functions, and Performance E52-CA20AY D=1.6 1M PDF catalog.
Handles More Applications.
The white PV display with a height of 15.2 mm improves visibility.
High-speed sampling at 50 ms.
Short body with depth of only 60 mm E52-CA20AY D=1.6 1M PDF catalog.
Easy connections to a PLC with programless communications.
Use component communications to link Temperature.
Controllers to each other.