Appearance: M8.
Sensing distance: 2 mm.
Connection method: M12 Connector Models.
Cable specifications: --.
Operation mode : NC .
Pin arrangement: 1: +V, 3: 0 V, 2: Control output.
Applicable connector code: D.
Model: NPN output.
Your Search for Proximity Sensors.
Starts with the World-leading E5AC-CC4ASM-005 PDF datasheet.
Performance and Quality of the E2E.
Standard Sensors for detecting ferrous metals
E5AC-CC4ASM-005
Wide array of variations. Ideal for a variety of applications.
Models with different frequencies are also available to prevent,
mutual interference.
Superior environment resistance with standard cable made of oil,
resistant PVC and sensing surface made of material that resists,
cutting oil.
Useful to help prevent disconnection E5AC-CC4ASM-005 PDF datasheet.
Cable protector provided as a standard feature. Free change detection direction.
Detection direction can be according to the front, side (up and down, around 90 units) change.
Can be similar to the feeling of a limit switch installation.
Type: DC type.
Shape: non shield.
Detection range: 30mm.
Output form: NO NPN + NC (dual output). Name: Basic Unit (temperature control) *1 E5AC-CC4ASM-005 PDF datasheet.
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: 2.
Control outputs 1 and 2: Voltage output: 2 points (for SSR drive) *2.
Control outputs 3 and 4: Transistor output: 2 points (sinking).
Auxiliary output: None.
Functions: burnout Heater alarm, 2 *3; Event inputs, 2 .
Communications functions: G3ZA connection port: RS-485,
From End Unit: Port A or port B: RS-485.
Input type: Thermocouple, platinum resistance thermometer,
analog voltage, and analog current selectable for each channel.
Terminal: M3 terminal.
In-panel Temperature Controller with Flexible,
Modular Design and Wide Integration with Host,
Devices.
The compact modular structure enables construction of temperature,
systems optimally suited to the application.
Connection can be made to a Programmable Controller without any,
programming required, reducing the number of steps required in ladder,
programming design.
One fully universal-input Unit includes a thermocouple, platinum-resistance,
thermometer, and analog input for easy selection and reduced inventory,
requirements.
Connect directly to the G3ZA Mullti-channel Power Controller using,
optimum cycle control for high-accuracy regulation with minimal noise E5AC-CC4ASM-005 PDF catalog.
Autotuning (AT) can be used for independent heating/cooling PID control.
Self-tuning (ST) can be used to calcullate the PID constants with the step,
response method E5AC-CC4ASM-005 PDF catalog.
Up to 16 Temperature Controllers can be connected to a single DeviceNet,
Communications Unit.