Power supply voltage: AC/DC power supply selectable type.
Sensing method: Diffuse-reflective.
Sensing distance: 300 mm.
Output configu ration: Relay.
Long-distance Photoelectric Sensor.
That Supports AC/DC Power Supplies.
Long sensing distance that is approximately 8,
times that of our conventional model (for the,
Through-beam and Diffuse-reflective models) E5EN-HSS2HH02BF-FLK PDF datasheet
E5EN-HSS2HH02BF-FLK
(Through-beam: 40 m, Retro-reflective: 7 m, and,
Diffuse-reflective: 2.5 m.) .
Improved visibility:
A red LED that makes the spot visible.
Large indicators that can be seen even from a,
distance.
Improved operability.
(Enlarged sensitivity adjuster and operation selector)
Freely selectable power supply input (24 to 240 VDC, 24 to 240 VAC) E5EN-HSS2HH02BF-FLK PDF datasheet.
(Additional types added to the DC type lineup.)
Models with infrared LEDs are also available. Type: Device Net.
The DeviceNet Communication Unit That.
Simplifies Managing Sensor Settings.
ON/OFF signals and incident light levels can be sent to the host,
PLC without any need for programming (DeviceNet communications,
slave functionality).
Threshold values and function settings can be read, written,
or taught (using the Message Communications function) E5EN-HSS2HH02BF-FLK PDF datasheet.
Simply connect the communication cables and slide the Amplifiers,
from the side for wire-saving.
Up to 16 Sensor Amplifiers can be connected. Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 3.2 dia.
Protective tubing length L: 35 cm.
Lead wire type: Heat resistive.
Lead wire length M: 4m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 96 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: RS-232C.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes the proocess of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output E5EN-HSS2HH02BF-FLK PDF catalog.
Through the infrared port can be carried out from the frront of the communication E5EN-HSS2HH02BF-FLK PDF catalog.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.