Size: 48 x 48mm.
Control output 1: current.
Auxiliary (alarm) output: 3.
Transfer output: -.
Event input: 2.
Communication: -.
Disconnection detection: 1.
Power supply voltage: DC24V/AC24V.
The white PV (current value) with excellent visibility shows the segment to make the confirmation work more easily E5EN-R3HT-W-N PDF datasheet.
Eye-catching white + industry''s largest display size
The black and white display and the industry''s largest display size to achieve excellent visibility
E5EN-R3HT-W-N
No matter from which angle or in the natural lighting environment, the dark scene,
Can quickly and accurately confirm the current value.
Displays the current value (PV/ white), the target value (SV/ green) and the progress of the program (PRG, SEG/ yellow) E5EN-R3HT-W-N PDF datasheet.
Can be viewed at the same time, there is no need to switch the display, so as to improve the efficiency of operations. Model: Shielded, M12.
Sensing distance: 2 mm.
Output configuration: DC 3-wire, NPN.
Model: Operation mode, NC.
Proximity Sensor with Resin Case,
with Superb Water Resistance.
IP68 protection.
Mutual interference prevention with models with different,
frequencies is also available E5EN-R3HT-W-N PDF datasheet. Size: 48 * 48mm, terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: -.
Event entry point: 2.
Transfer output: transfer output (special terminal).
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thhermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV E5EN-R3HT-W-N PDF catalog.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can performm flexible contact output E5EN-R3HT-W-N PDF catalog.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.