Number of phase: Single-phase.
Control terminal block: Terminal block with small slotted screws.
Type: Constant current.
Capacity: 20 A, 100 to 240 VAC.
Heater burnout detection: Yes.
Communications: Yes.
High-precision Control with Easy Setup,
Precise heater burnout detection.
Set value and present value monitoring with indicators G3RV-202SL DC24 PDF datasheet.
Phase control or optimum cycle control
G3RV-202SL DC24
RS-485 communications to set manipulated variables and,
monitor load current.
Total run time monitoring.
Output modes for phase control: proportional to phase angle,
proportional to voltage, proportional to square voltage,
and constant-current control.
Application with various loads: constant load resistance,
variable load resistance G3RV-202SL DC24 PDF datasheet.
UL, and IEC/EN (TÜV) certified. Type: Standard.
Sealing: Flux-tight.
Poles: 6 poles.
Contact configuration: 5PST-NO, SPST-NC.
Rated voltage: 12, 18, 21, 24, 48, 110 VDC.
Compact, Slim Relays Conforming to,
EN Standards.
Relays with forcibly guided contacts,
(EN50205 Class A, certified by VDE).
Supports the CE marking of machinery (Machinery Directive).
Helps avoid hazardous machine status when used as part of,
an interlocking circuit G3RV-202SL DC24 PDF datasheet.
Four-pole and six-pole Relays are available.
The Relay’s terminal arrangement simplifies PWB pattern design.
Reinforced insulation between inputs and outputs.
Reinforced insulation between some poles of different polarity. Main contacts: DPST-NO.
Auxiliary contact: None.
Number of input channels: 2 channels.
Reset mode: Manual reset.
Input type: Inverse.
Rated voltage: 24 VAC/VDC.
Ultra Slim Safety Relay Unit.
Models of width 17.5 mm available with 2 or 3 poles. Models.
of width 22.5 mm with 3 poles also available.
Conforms to EN standards. (TÜV approval).
DIN track mounting possible. No. of steps: 12.
Rated voltage: 24 VDC, 100 VAC, 200 VAC.
Ideal for Controlling Pumps and Production.
Lines with Six or Twelve Stepping Circuits.
Built-in relays switch 2 A at 250 VAC or 30 VDC.
Initialization of stepping with reset input.
Uses memory that stores setting status for 10 days without.
power. All internal contacts are released when no power is supplied.
Detectss an internal element malfunction caused by external G3RV-202SL DC24 PDF catalog.
noise, indicates the malfunction with an alarm indicator, and,
turns the relay alarm output ON. (An internal relay malfunction,
or internal relay contact weld cannoot be detected G3RV-202SL DC24 PDF catalog. ).
With safety-design terminals which prevent electric shock accidents.
With easy-to-see indicators which display the stepping status.