Number of phases: Three-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: Yes.
Type: DIN track mounting *2.
Applicable load: 35 A, 100 to 240 VAC.
Number of pole: 2.
Compact, Slim-profile SSRs with Heat Sinks G7S-E Series PDF datasheet.
Solid State Contactors for Three-phase.
Heaters Reduced Installation Work
G7S-E Series
with DIN Track Mounting.
RoHS compliant.
Surge pass protection improved surge dielectric strength,
for output currents. (OMRON testing).
Slim design with 3-phase output and built-in heat sinks.
DIN Track mounting types and screw mounting types are available.
All DIN Track mounting types mount to DIN Track.
(applicable DIN Track: TR35-15Fe (IEC 60715)) G7S-E Series PDF datasheet.
Conforms to UL, CSA, and EN standards (TÜV certification). Terminal (wire connection): Screw terminal.
Applicable output load: AC load.
Zero cross function: Yes.
Rated input voltage: AC 110V.
Global standard size,
low profile slim I/O relay with width 6.2 mm,
slim I/O solid state relay.
Realized about 25% lower profile than conventional,
products, contributing to further miniaturization of the,
control panel G7S-E Series PDF datasheet.
Push-In Plus terminal blocks are used to save wiring work,
in comparison with conventional screw terminals.
(Wiring time is reduced by 60%* in comparison with,
traditional screw terminals.).
No screw loosening means maintenance-free application,
realizing high reliability.
Hand-free structure that holds an inserted flat-blade,
screwdriver to achieve easier wiring work for stranded wires.
Screw terminal is also stocked to meet the screw type needs.
Mounted relay or solid-state relay has a plug-in terminal.
that is difficult to bend at the time of exchange. Input terminals: M3 terminals.
Isolation method: Phototriaccoupler.
Zero cross function: Yes.
Operation indicator: Yes.
Alarm output: 1 output (Heater Burnout Detection,
SSR Short-circuit Failure Detection, Common).
Applicable load (See note.): 2 to 35 A, 100 to 240 VAC.
A New-concept SSR with Built-in.
Current Transformer.
Heater Burnout and SSR Short.
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps.
Detects the burnout of any one of a group of heaters.
Detects the burnout of 3-phase heaaters G7S-E Series PDF catalog.
Detects SSR short-circuit failures.
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws.
Three types of input terminals available: M3 terminals,
screwless clamp termiinals (detachable), or compact slotted,
screw terminals (detachable) G7S-E Series PDF catalog.
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified.