Safety outputs: --.
Safety standstill detection output: 3.
Auxiliary output: 2.
Rated voltage: 24 VDC.
Terminal block type: Spring-cage terminals.
Sensor-less Monitoring of Standstill for,
Machines with Long Inertia.
Standstill is monitored by the motor''s back electromotive force (BEMF) signal GT1-AD04 PDF datasheet.
Features a "Standard Configuration", allowing immediate use,
without sensitivity adjustment
GT1-AD04
"User Configuration" also available for fine-tuning of sensitivity.
Detailed LED indications enable easy fault diagnosis.
Safety Category 4 (EN954-1), PLe(ISO13849-1),
SIL 3 (IEC/EN 62061) certified. Safety outputs *3: Instantaneous, 2(semiconductor);
OFF-delayed *2: 2 (semiconductor).
Auxiliary outputs *4: 6 (semiconductor) GT1-AD04 PDF datasheet.
Logical AND connection: Inputs, 1 (semiconductor);
Outputs, 1 (semiconductor).
Max.OFF-delay time *1: 15 s.
Rated voltage: 24 VDC.
Terminal block type: Spring-cage terminals.
A Safety Measure for Hazardous Operations.
That Does Not Lower Productivity.
Two functions support two types of application:
Auto switching: For applications where operators work,
together with machines GT1-AD04 PDF datasheet.
Manual switching: For applications with limited operations.
External indicator outputs enable indicating the switching status,
of two safety input devices.
Auxiliary outputs enable monitoring of safety inputs, safety,
outputs, and errors.
Detailed LED indications enable easy diagnosis.
Logical AND connection allows complicated applications in,
combination with other G9SX-series Units.
Certification for compliance with IEC/EN 61508 (SIL3), IEC/EN,
62061 (SIL3) and EN ISO13849-1 (PLe/Safety Category 4). High-power, Load-control SSRs with.
High Current of 75 or 150 A and High.
Voltage of 240 or 480 VAC.
RoHS compliant.
Models also available with no zero cross.
Replaceable power elements.
Conforms to cULus standards and EN standards (TÜV certification). Number of phases: Single-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: Yes.
Applicable load: 35 A, 100 to 240 VAC.
Compact, Slim--profile SSRs with Heat,
Sinks GT1-AD04 PDF catalog. Models with No Zero Cross for,
a Wide Range of Applications.
RoHS compliant.
Models also available with no zero cross,
Surge pass protection improved surge dielectric strength for,
output cuurrents GT1-AD04 PDF catalog. (OMRON testing).
Compact with a slim profile.
Mount to DIN Track or with screws.
Conforms to UL, CSA, and EN standards (TÜV certification).