OMRON
Home >> Download >> OMRON >> Catalog Download >> K3HB-CNB-AT11 AC100-240 PDF datasheet (datasheet)

K3HB-CNB-AT11 AC100-240 PDF datasheet (datasheet)

Brand: OMRON
Product model: K3HB-CNB-AT11 AC100-240
Name: Cumulative / increase / decrease pulse meter
Sort: PDF datasheet
File language: English
File size: 1.34MB
Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (S-TMR, HOLD, RESET) is equipped with.
External power 80mA DC12V.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
Communication: RS-232C; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth K3HB-CNB-AT11 AC100-240 PDF datasheet.
Power supply voltage: AC/DC24V.
Digital rotating pulse meter with high speed measurement for 50kHz K3HB-CNB-AT11 AC100-240
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of 50kHz high speed pulse.
Can rotate the encoder and a variety of ON/OFF pulse signal, up to 5Time specification: Instantaneous type.
Current setting range: 8 to 26 A.
Operating voltage: 400/440 VAC K3HB-CNB-AT11 AC100-240 PDF datasheet.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation K3HB-CNB-AT11 AC100-240 PDF datasheet.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Power supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 0.200 to 2.200 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and ccyclic control K3HB-CNB-AT11 AC100-240 PDF catalog.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreent relay or for motor or lamp loads K3HB-CNB-AT11 AC100-240 PDF catalog.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).
Related products
OMRON
Load sensor, mV instrument
K3HB-VLC-BT11 AC100-240
OMRON Load sensor, mV instrument K3HB-VLC-BT11 AC100-240
Category: external supply 100mA DC10V. Input
OMRON
Time interval table
K3HB-PNB-CPAC11 AC100-240
OMRON Time interval table K3HB-PNB-CPAC11 AC100-240
Input type: NPN/ voltage pulse input type. E
OMRON
Voltage and current panel meter
K3HB-XAA-L1AT11 AC100-240
OMRON Voltage and current panel meter K3HB-XAA-L1AT11 AC100-240
Type of input: AC current input. Output type