Time specification: Inverse type.
Current setting range: 50 to 160 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage K3HB-HTA-L1AT11 AC/DC24 PDF datasheet.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase
K3HB-HTA-L1AT11 AC/DC24
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-HTA-L1AT11 AC/DC24 PDF datasheet. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Appearance: circular shell embedded R2.
Static type reverse electric relay K2WR type.
Reverse power relay for household and marine generator K3HB-HTA-L1AT11 AC/DC24 PDF datasheet.
A high precision power detection can be performed by the analog time division multiplier.
Through the rated voltage of the switch, adjust the current simulation of variable,
Can correspond to the rated value of all generators.
Due to the instant start in contact, the response difference is minimal,
Position detection with high accuracy. Sharing with voltage input, no need to control the power supply.
Because it is static, so the anti vibration impact ability, action stability.
Equipped with easy to manage and maintain the boot display with LED. A collection of shell: the shell embedded R2 shell.
Purpose: high voltage non grounding system.
Static ground directional relay K2GS-B type,
Advanced ground direction relay corresponding to the diversification of ground fault.
Feeder priority cut-off function for coordinated multi segment setting.
Prevention of low frequency vibration with other circuit accidents,
Circuit for locking circuit and preventing effect of electric wave caused by false action,
In order to improve the reliability.
Thee coordination device for the zero phase action voltage is set up,
Therefore, the influence of the residual voltage can be avoided K3HB-HTA-L1AT11 AC/DC24 PDF catalog.
Due to the built-in filter, so in the event of the occurrence of the ramp wave innput can also maintain a stable role,
Because of the signal level detection, it is easy to carry out the action experiment and set up the confirmation K3HB-HTA-L1AT11 AC/DC24 PDF catalog.