Ideal for Monitoring 3-phase Power.
Supplies for Industrial Facilities and Equipment.
Greater resistance to inverter noise.
Monitor overvoltages, undervoltages, phase sequence,
and phase loss for three-phase 3-wire or 4-wire power,
supplies with just one Unit.
Switch setting for 3-phase 3-wire or 3-phase 4-wire power supply K3HB-P Series PDF datasheet.
Two SPDT output relays, 5 A at 250 VAC (resistive load)
K3HB-P Series
Output overvoltages and undervoltages using separate relays.
World-wide power specifications supported by one Unit (switchable).
Output status can be monitored using LED indicator. Measuring voltage: 6 to 60 mV AC/DC, 10 to 100 mV AC/DC, 30 to 300 mV AC/DC.
Supply voltage: 24 VAC/DC.
Ideal for voltage monitoring for industrial K3HB-P Series PDF datasheet.
facilities and equipment.
Monitor for overvoltages and undervoltages simultaneously.
Separate settings and outputs supported for overvoltages and,
undervoltages.
Manual resetting and automatically resetting supported by one Relay.
Pre-alarm Monitoring Mode.
Two SPDT output relays, 6 A at 250 VAC (resistive load).
Process control signal (0 to 10 V) and current splitter input supported K3HB-P Series PDF datasheet.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply. Control supply voltage: 110 VAC; With voltage fluctuation compensation.
Operating current: 8 to 20 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out.
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage. Standard function model: detection of under voltage.
Appearance: ADR shell.
Open circuit: voltage, no voltage, DC circuit breaker.
Rated voltage: AC110V.
Rated frequency: 50/60Hz.
Voltage adjustment range: 60-65-70-75-80-85-90-95-100V (9 shunt).
Time hopping: timing; 0.1-0.2-0.4-0.6-0.8-1.0-1.2-1.4-1.6-1.8-2.0s (11 shunt).
Control power supply: and input common.
Rated consumption VA:7VA.
Control output: 1C, 1A closed 110V 15A1000 L/R=0ms times (DC);
Open 110V 1A DC 1000 (L/R=25ms).
Display: display resolution 1V (display range: 50-130V).
Automatic experiment: there.
Quality: about 1kg.
External: Mount Searl N1.5.
Digital voltage relay series.
K2VU-H/K2VA-H type, large range of adjustmment shunt,
Easy to coordinate digital VR K3HB-P Series PDF catalog.
And the automatic tester with convenient for relay testing.
Measurable voltage value.
The reliability can be improved by monitoring the function at any time.
The forced action of tthe experimental switch can be easily recognized K3HB-P Series PDF catalog.
Exterior dimension based on DIN standard,
The depth is only the size of the 88.5mm (terminal except).