OMRON
Home >> Download >> OMRON >> Catalog Download >> K3HB-VLC-CPBC21 AC100-240 PDF datasheet (datasheet)

K3HB-VLC-CPBC21 AC100-240 PDF datasheet (datasheet)

Brand: OMRON
Product model: K3HB-VLC-CPBC21 AC100-240
Name: Load sensor, mV instrument
Sort: PDF datasheet
File language: English
File size: 1.48MB
Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (HOLD, RESET) equipped with.
External power supply DC12V80mA.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
Linearity: voltage; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V K3HB-VLC-CPBC21 AC100-240 PDF datasheet.
Measurement of 2 points through the speed, time, or cycle of the digital time interval table K3HB-VLC-CPBC21 AC100-240
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of wide range of pulse interval time.
Measuring, calculating and displaying the pulse interval between 2 points.
Pulse interval measurement range, maximum measurableTime specification: Instantaneous type K3HB-VLC-CPBC21 AC100-240 PDF datasheet.
Current setting range: 50 to 160 A.
Operating voltage: 400/440 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase K3HB-VLC-CPBC21 AC100-240 PDF datasheet.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 20.0 to 200.0 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cycclic control K3HB-VLC-CPBC21 AC100-240 PDF catalog.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreent relay or for motor or lamp loads K3HB-VLC-CPBC21 AC100-240 PDF catalog.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).
Related products
OMRON
Voltage and current panel meter
K3HB-XVA-CPAC21 AC100-240
OMRON Voltage and current panel meter K3HB-XVA-CPAC21 AC100-240
Type of input: AC voltage input. Output type
OMRON
Temperature panel
K3HB-HTA-CPAC21 AC100-240
OMRON Temperature panel K3HB-HTA-CPAC21 AC100-240
Type of input: platinum resistance / thermoco
OMRON
Load sensor, mV instrument
K3HB-VLC-CPBC21 AC100-240
OMRON Load sensor, mV instrument K3HB-VLC-CPBC21 AC100-240
Category: external supply 100mA DC10V. Input
OMRON
Voltage and current panel meter
K3HB-XVD-CPAC21 AC100-240
OMRON Voltage and current panel meter K3HB-XVD-CPAC21 AC100-240
Input type: DC voltage input type. Output ty