Brand: OMRON
Product model: K3HB-XAA-FLK1AT11 AC100-240
Name: Voltage and current panel meter
Sort: PDF datasheet
File language: English
File size: 1.90MB
Time specification: Instantaneous type.
Current setting range: 50 to 160 A.
Operating voltage: 400/440 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage K3HB-XAA-FLK1AT11 AC100-240 PDF datasheet.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase K3HB-XAA-FLK1AT11 AC100-240
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-XAA-FLK1AT11 AC100-240 PDF datasheet. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Time specification: Instantaneous type.
Current setting range: 20 to 65 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic K3HB-XAA-FLK1AT11 AC100-240 PDF datasheet.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation, Category: external supply 100mA DC10V.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
BCD+ transistor: -- NPN open collector (5 bit output +HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply vvoltage: AC/DC24V K3HB-XAA-FLK1AT11 AC100-240 PDF catalog.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified.
Actioon determine the color, can switch the green / Red 2 kinds of color display K3HB-XAA-FLK1AT11 AC100-240 PDF catalog.
Equipped with the sub pressure gauge for monitoring the operation trend.
Related products
OMRON
Rotating pulse meter
K3HB-RPB-FLK3AT11 AC100-240
OMRON Rotating pulse meter K3HB-RPB-FLK3AT11 AC100-240
Input type: PNP input type. Event input term
OMRON
Voltage and current panel meter
K3HB-XAA-L2AT11 AC100-240
OMRON Voltage and current panel meter K3HB-XAA-L2AT11 AC100-240
Type of input: AC current input. Output type
OMRON
Rotating pulse meter
K3HB-RNB-L2AT11 AC100-240
OMRON Rotating pulse meter K3HB-RNB-L2AT11 AC100-240
Input type: NPN/ voltage pulse input type. E
OMRON
Voltage and current panel meter
K3HB-XVD-AT11 AC100-240
OMRON Voltage and current panel meter K3HB-XVD-AT11 AC100-240
Input type: DC voltage input type. Output ty