Type: related equipment (sold separately); split type current transformer (CT).
Rated primary side current: 100A.
Rated two secondary current: 1A.
Simple monitoring of the use of electricity to support energy saving countermeasures.
On behalf of the use of the mechanical equipment, the measurement of the initial voltage, current,
Cumulative quantity, invalid power, power factor, frequency K8AB-PA2 PDF datasheet
K8AB-PA2
To achieve a simple record with a memory card. (with memory card function model)
The measurement data can be stored in the main body, and the centralized monitoring and management can be carried out in the communication network.
Wide 45mm miniaturization, simple set to the DIN guide. Appearance: square shell embedded F1 K8AB-PA2 PDF datasheet.
Static type reverse electric relay K2WR type.
Reverse power relay for household and marine generator.
A high precision power detection can be performed by the analog time division multiplier.
Through the rated voltage of the switch, adjust the current simulation of variable,
Can correspond to the rated value of all generators.
Due to the instant start in contact, the response difference is minimal,
Position detection with high accuracy K8AB-PA2 PDF datasheet. Sharing with voltage input, no need to control the power supply.
Because it is static, so the anti vibration impact ability, action stability.
Equipped with easy to manage and maintain the boot display with LED. Ideal for monitoring 3-phase power supplies.
for industrial facilities and equipment.
Monitor overvoltages, undervoltages, phase sequence, and,
phase loss for three-phase 3-wire or 4-wire power supplies with,
just one Unit.
Switch setting for 3-phase 3-wire or 3-phase 4-wire power,
supply.
Two SPDT output relays, 6 A at 250 VAC (resistive load).
Output overvoltages and undervoltages using separate relays.
World-wide power specifications supported by one Unit,
(switchable).
Output status can be monitored using LED indicator. Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 2.00 to 22.00 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phasee control, and cyclic control K8AB-PA2 PDF catalog.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreent relay or for motor or lamp loads K8AB-PA2 PDF catalog.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).