OMRON
Home >> Download >> OMRON >> Manual Download >> 3G2A5-RM001-EV1 INSTRUCTION SHEET ()

3G2A5-RM001-EV1 INSTRUCTION SHEET ()

Brand: OMRON
Product model: 3G2A5-RM001-EV1
Name: Safety Light Curtain
Sort: INSTRUCTION SHEET
File language: English
File size: 1.04MB
Connect PC/AT IBM or compatible machine, as LINK SYSMAC system node.Specification: three phase 400V.
Power: 220KW.
Maximum output voltage: three phase AC380 ~ 480V (input voltage correspondence).
Rated voltage: three phase 480V ~ 50/60Hz AC380.
Weight: about 280kg.
In the inverter is equipped with the servo can play the same static torque with PG vector control function,
DeviceNet communication makes the application field more extensive 3G2A5-RM001-EV1 INSTRUCTION SHEET 3G2A5-RM001-EV1
The high functional specifications are concentrated in the compact.
Equipped with PG vector control.
Subsequent models of 3G3RV.
CV/VT selection function.
Rich online automatic adjustment function (self learning function).
CX-Drive software.
DeviceNet correspondence correspondence 3G2A5-RM001-EV1 INSTRUCTION SHEET.
Multi function input and output function.
Colorful function.
Brake transistor built-in.
Protection function. Power supply: 3 phase 3 line rated voltage 500V AC.
Rated current: 12A.
Weight: 0.9KG.
Used to reduce the noise generated by the inverter.
Try to be close to the transducer for connection. When the power supply capacity exceeds the power supply capacity of the inverter or the need to improve the power factor, it is required to connect the AC reactor 3G2A5-RM001-EV1 INSTRUCTION SHEET.
Please according to the maximum capacity of heavy load and light load rated conditions suitable for motor to select option. Inverter input power: 3 phase / single phase AC200V.
Weight: 1.6KG.
Standard applicable line diameter: 2 square mm or more.
Used to suppress harmonic currents generated by a transducer.
The effect of harmonic current suppression is better than that of AC reactor,
And it can be used with AC reactor. Box protection class: plastic, IP00.
Terminal size: M4.
Line diameter: 1.25 square mm, 2 square mm.
Weight: 0.7kg.
Used to reduce the noise from the power cord to the frequency converter or from the frequency converter to the power line 3G2A5-RM001-EV1 Manual.
Try to be close to the transducer for connection. Box protection class: plastic, IP00.
Terminal size: M4.
Line diameter: 2 square mm, 3.5 square mm.
Weight: 0.7kg.
Used to reduce the noiise from the power cord to the frequency converter or from the frequency converter to the power line 3G2A5-RM001-EV1 Manual.
Try to be close to the transducer for connection.
Related products
OMRON
SYSBUS Remote I/O Unit
C500-RT201(3G2A5-RT201)
OMRON SYSBUS Remote I/O Unit C500-RT201(3G2A5-RT201)
C500-RT SYSMAC BUS Remote I/O Master Slave Wi
OMRON
SYSBUS Remote I/O Unit
C500-RT002-PV1(3G2A5-RT002-PV1)
OMRON SYSBUS Remote I/O Unit C500-RT002-PV1(3G2A5-RT002-PV1)
C500-RT SYSMAC BUS Remote I/O Master Slave Wi
OMRON
SYSBUS Remote I/O Unit
C500-RT001-V1(3G2A5-RT001-V1)
OMRON SYSBUS Remote I/O Unit C500-RT001-V1(3G2A5-RT001-V1)
C500-RT SYSMAC BUS Remote I/O Master Slave Wi
OMRON
SYSBUS Remote I/O Unit
C500-RM201(3G2A5-RM201)
OMRON SYSBUS Remote I/O Unit C500-RM201(3G2A5-RM201)
C500-RM SYSMAC BUS Remote I/O Master Wired C5