OMRON
Home >> Download >> OMRON >> Manual Download >> 3G3MX2-A4075-Z INSTRUCTION SHEET ()

3G3MX2-A4075-Z INSTRUCTION SHEET ()

Brand: OMRON
Product model: 3G3MX2-A4075-Z
Name: Time lnterval Meter
Sort: INSTRUCTION SHEET
File language: English
File size: 1.93MB
Specification: single phase 200V
Power: 0.75KW.
Maximum output voltage: three phase input voltage.
Rated voltage, frequency: single phase power supply 200 ~ 50/60Hz, 240V.
Cooling way: natural wind cooling.
Weight: 1.1kg.
Open loop vector control mode of low speed and high torque, rich control function and convenient distribution management network function,
Set in one of the inverter --3G3MZ 3G3MX2-A4075-Z INSTRUCTION SHEET 3G3MX2-A4075-Z
3G3MZ series inverter for the application of frequency control and development.
Humanized design and advanced management technology, as well as OMRON a simple style of modeling, feature rich style,
Combined with the latest technical needs of users, so that it has a noble lineage and the most close to the market elements 3G3MX2-A4075-Z INSTRUCTION SHEET.
Covers the special features of the fan pump class, open loop vector function,
Built in noise filter and a variety of network bus,
3G3MZ will be your most economical and the most perfect choice. Function name: 3 phase 400V.
Power: 2.2KW.
Rated output voltage: 3 phase, 380 ~ 480V (the output voltage can not exceed the input voltage).
Built in brake unit (brake resistance needs to be matched) 3G3MX2-A4075-Z INSTRUCTION SHEET.
Weight: 1.9KG.
Dimension (w * h) 128mm *:108.
Outline dimension (deep):170.5mm.
Mechanical automation concept.
Positioning function.
The use of options.
(EtherCAT, CompoNet and DeviceNet) to realize the field bus communication.
Driver programming function.
Current vector control.
High starting torque: 0.5Hz up to 200%.
Safety features, in compliance with ISO13849-1:2008 EN (Cat.3/PLd) and IEC60204-1 stop level 0 standard.
Frequency output up to 580H. Inverter input power: 3 phase / single phase AC200V.
Weight: 2.1KG.
Standard applicable line diameter: 2 square mm or more.
Used to suppress harmonic currents generated by a transducer.
The effect of harmonic ccurrent suppression is better than that of AC reactor,
And it can be used with AC reactor 3G3MX2-A4075-Z Manual. Box protection class: plastic, IP00.
Terminal size: M4.
Line diameter: 2 square mm, 3.5 square mm.
Weight: 0.7kg.
Used to reduce the noiise from the power cord to the frequency converter or from the frequency converter to the power line 3G3MX2-A4075-Z Manual.
Try to be close to the transducer for connection.
Related products
OMRON
Multi function small frequency converter
3G3MX2-A2001-ZV1
OMRON Multi function small frequency converter 3G3MX2-A2001-ZV1
Function name: 3 phase 200V. Power: 0.1KW. Ra
OMRON
Multi function small frequency converter
3G3MX2-A4075-ZV1
OMRON Multi function small frequency converter 3G3MX2-A4075-ZV1
Function name: 3 phase 400V. Power: 7.5KW. Ra
OMRON
Multi function small frequency converter
3G3MX2-A4007-ZV1
OMRON Multi function small frequency converter 3G3MX2-A4007-ZV1
Function name: 3 phase 400V. Power: 0.75KW. R
OMRON
Multi function small frequency converter
3G3MX2-A4110-ZV1
OMRON Multi function small frequency converter 3G3MX2-A4110-ZV1
Function name: 3 phase 400V. Power: 11KW. Rat