Specifications: 4 Kwords with clock.Unit type: CS1 Basic I/O Units.
Product name: Relay Output Units.
Specifications: 250 VAC or 120 VDC,
2 A max. 16 outputs.
Mountable Racks: CPU Rack, CS1W-BC,
@@3, Yes, @@2, Yes;
C200HX/HG/HE Expansion I/O Rack, No.
CS1 Expansion Rack, CS1W-BI,
@@3, Yes, @@2, Yes;
CS1 Long distance Expansion Rack, Yes;
SYSMAC BUS Slave Rack, No C200HG-CPU33-E HOST CONNECTION MANUAL
C200HG-CPU33-E
Words required: 1 word.
Current consumption: 5V system, 0.13A;
26 V system, 0.006per simultaneously ON outputs.
Standards: UC1, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control. Specification: Thermocouple input, transistor (NPN) output, 2 loops.CPU Unit: CP1L-L CPU Units with 10 Point C200HG-CPU33-E HOST CONNECTION MANUAL.
Specifications: CPU type, Memory capacity: 5K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, DC power supply; Output method, Relay output;
Inputs, 6; Output, 4.
Standards: UC1, N, L, CE.
High Performing Programmable Controller with Embedded Ethernet.
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port C200HG-CPU33-E HOST CONNECTION MANUAL.
"CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams. NO. OF I/O SLOTS: 3 SLOTSProduct name: CS1 Expansion Backplanes.
Specifications: For CS-series,
Unit only Note: C200H series,
Units cannot be mounted; 10 slots.
Mountable configuration units:
Basic I/O Units, CS-series Basic I/O Unit,
Yes; C200H series Basic I/O Unit, No;
C200H Group-2 High density I/O Unit, No.
Special I/O Units: CS-series Special I/O Unit,
Yes; C200H series Special I/O Unit, No.
CPU Bus Units: CS-series CPU Bus Unit, Yes.
Current consumption: 5V system, 0.23A;
26 V system, --.
Standards: U, C, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control. Name: e-CON Connectors.
Specifications: Inputs; 16 inputs; NPN;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced C200HG-CPU33-E Manual.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee C200HG-CPU33-E Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.