File size: 11.52MB
C200HW Communications Interface Module C200HW-PRM21C500-ID Special I/O Unit ID Sensor Unit Long-distance C500-IDS22.C200H-CPU01-E/C200H-CPU03-E CPUs
High Spec, Small Rack Style,
OEM Version The C200H-CPU01-E and C200H-CPU03-E controllers offer big machine functions in a system designed ideally for basic OEM systems from 50 to 480 I/O CJ1G-CPU43H SYSTEM MANUAL.
A wide variety of plug-in style I/O modules are available,
including intelligent modules CJ1G-CPU43HModel: C200HW-CORT21-V1.
C200HW C Communications CANopen Master / Slave Unit C200HWCORT21Model: C200H-IA221.
No. of inputs: 8 pts.
Input voltage: 200 to 240 VAC, +10%/–15%.
Input current: 10mA, 200VAC.
Isolation: Photo-coupler.
Indica-tor: LED.
External connec-tions: Remove-able termi-nal blocks CJ1G-CPU43H SYSTEM MANUAL.
Inputs percom-mon: 8 pts.
Internal currentcon-sump-tion: C500-RT SYSMAC BUS Remote I/O Master Slave Wired C500-RT201.
Master station unit remote I/O.Number of inputs: 8 pts.
Input Voltage: 100 to 120V DC.
Input Current: 5 mA.I/O bits: 5, 120 (Expan-sion Racks: 7).
Program capacity: 20K steps.
Data memory capacity: 64K words (DM: 32K words, EM: 32K words ×1 banks) CJ1G-CPU43H SYSTEM MANUAL. Unit classification: CJ1 Special I/O Units.
name: Position control unit.
Specifications; Control method/Control,
output interface:Open-loop control by pulse,
train output/Line-driver output;
Number of control axes : 1 axis.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.25A; 24V, --.
Standards: UC1, CE.
High-speed, High-precision positioning,
with 1, 2, or 4 axes.
Versatile functions and superb performance,
enable the construction of compact,
high-performance machines.
With its ultra-compact size of 31 × 90mm (W×H),
this highly space-efficient Position Control Unit,
(PCU) enables up to 4 axes of motor control. Specification: Platinum resistance thermometer input (Pt100, JPt100),
heater burnout alarm,
manual operation,
ON/OFF or advanced PID control,
transistor (PNP) output, 2 loops.Unit type: CJ1 Basic I/O Units.
name: B7A Interface Units.
Specifications: I/O points, 32 inputs/outputs;
External connection, Removable terminal block.
No. of words allocated: 4 words.
Current consumption: 5V, 0.07A; 24V, --.
Standards: UC1, CE.
It transmmits 16 points of I/O signals per,
word with a pair of cables CJ1G-CPU43H Manual.
Easy and minimized wiring effort,
The B7A Interface Unit and B7A Link Terminal,
can be used in the same way as a standard,
Basic I/O Unit and I/O Terminal withoutt,
any need to worry about communications CJ1G-CPU43H Manual.
This characteristic reduces the wiring,
when using more than one relatively remote,
sensor or actuator.
Related products
OMRON
Programmable Controllers
CJ1G-CPU42H
OMRON Programmable Controllers CJ1G-CPU42H
I/O capacity/Mountale Units Expansion Racks
OMRON
Programmable Controllers
CJ1G-CPU43H
OMRON Programmable Controllers CJ1G-CPU43H
I/O capacity/Mountale Units Expansion Racks
OMRON
Programmable Controllers
CJ1G-CPU44P
OMRON Programmable Controllers CJ1G-CPU44P
Name: Loop-control CPU Unit. I/O its: 1,2
OMRON
Programmable Controllers
CJ1G-CPU45H
OMRON Programmable Controllers CJ1G-CPU45H
I/O capacity/Mountale Units Expansion Racks