Product name: N@@-type CPU Units with 30 I/O Points.
Specifications: Power Supply, 24 VDC; Inputs, 18; Outputs, 12;
Output type: Relay.
Program capacity: 8K steps.
memory Data capacity: 8K words.
External powersupply(24 VDC): --.
Current consumption: 5 V, 0.21A; 24 V,0.07A.
Standards: UC1, N, L, CE CP1E-N30S1DR-A USER'S MANUAL.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient
CP1E-N30S1DR-A
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. Supply voltage: 100 to 240 V AC, 50/60 Hz (wide range).
Operating voltage range: 85 to 265 V AC CP1E-N30S1DR-A USER'S MANUAL.
Output capacity: 5 V DC: 6 A 24 V DC: 0.5 A(30 W total, see note).Product name: CJ1M CPU Units; Without built-in I/O.
Specifications: I/O capacity/Mountable Units Expansion Racks),
160 points/10 Units (No Expansion Rack); Program capacity,
5K steps; Data memory capacity, 32K words(DM: 32K words, EM: None);
LD nstruction execution time, 0.1 μs.
Current consumption: 5v, 0 CP1E-N30S1DR-A USER'S MANUAL. 58A (Seenote 1.) ; 24V,--.
Standards: UC1, N, L, CE.
Versatile Machine Control with the,
Highest Performance Standards in the Industry. Unit type: CS1 Special I/O Units.
Product name: Isolated-type Resistance,
Thermometer Input Units (Ni508.4 Ω).
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: INi508.4.
Conversion speed (resolution):
100 ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.15A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems CP1E-N30S1DR-A Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CP1E-N30S1DR-A Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.