Name: Screw Terminal Block with Relay Outputs.
Specifications: Outputs;
8 outputs; Contacts.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system CP1E-N30SDT-D REFERENCE MANUAL.
A wide variety of CompoNet Slave Units,
contribute to system size reduction
CP1E-N30SDT-D
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Model: CPM2C-32CDT1C-D. CPU Unit: Units with 32 I/O points.
2 Fujitsu connectors.
Inputs: 16 inputs CP1E-N30SDT-D REFERENCE MANUAL.
Outputs: 16 outputs.
Input type: 24 VDC.
Output type: sourcing transistor.
Internal clock: --.Connects Power Supply Adapter and SYSMAC NET Link Unit.
Included with C200H-APS01.Model: C200H-OD216.
No. of points: 8 pts.
Specifications: 0.8 A, 24 VDC. source type (PNP). with load short protection.Name: Position Control Module.
Model: C200H-NC112.
Control method: Open-loop, automatic trapezoid acceleration/deceleration CP1E-N30SDT-D REFERENCE MANUAL.
Control output sig-nals: Pulse-train outputs.
Controlled axes: 1.C500-CT/3G2A5-CT Special I/O Unit High-speed Counter 50 kcps 1 pts C500-CT001(3G2A5-CT001).Unit type: CS1 Special I/O Units.
Product name: Analog Input Unit (100 mV).
Input points : 8 inputs.
Signal range: 0 to 100 mV, ±100 mV.
Conversion speed (resolution):
200ms/8 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.08A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and spacee compared,
with previous systems CP1E-N30SDT-D Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CP1E-N30SDT-D Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.