Model: C200H-OD218.
No. of points: 32 pts.
Specifications: nit 4.5 VDC, 16 mA to 26.4 VDC, 100 mA. .
Weight: 180g max.Unit type: CS1 Special I/O Units.
Product name: Isolated-type DC Input Unit.
Input points : 4 inputs.
Signal range: 4 to 20 mA, 0 to 20 mA,
1 to 5 V, 0 to 5 V, ±5 V, 0 to 10 V, ±10 V CP1E-N60SDT1-D PROGRAMMING MANUAL.
Conversion speed (resolution):
100ms/4 inputs.
Externa connection: Removable erminal block
CP1E-N60SDT1-D
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.16A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value CP1E-N60SDT1-D PROGRAMMING MANUAL.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems CP1E-N60SDT1-D PROGRAMMING MANUAL.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools. Model: CPM2C-10C1DT1C-D. CPU Unit: Units with 10 I/O points.
2 Fujitsu connectors.
Inputs: 6 inputs.
Outputs: 4 outputs.
Input type: 24 VDC.
Output type: sourcing transistor.
Internal clock: Yes.Inputs: 8.OMRON PID Module C500-PID01(3G2A5-PID01-E)Model: C500-CN122N.
Cable length 1m.
CV Series C Series Expansion ← → I / O device CPU Connecting cable(Vertical-wired)Name: Screw Terminal Block with Relay Outputs.
Specifications: Outputs;
8 outputs; Contacts.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced CP1E-N60SDT1-D Manual.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CP1E-N60SDT1-D Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.