CVM1-LK SYSMAC BUS CVM1 PCLINK MODULE CVM1-LK401.I/O Cable (for I/O to Interface Racks) 0.3 m (L) CV500-CN3124 Axis Position Control and Comprehensive Programmable Controller.
The CP1H-X with pulse outputs for 4 axes.
The CP1H-Y with 1-MHz pulse I/O.
The CP1H-XA with pulse outputs for 4 axes and built-in analog I/O CP1H-X40DT-D HOST CONNECTION MANUAL. Model: C200HW-ME08K.
Capacity: 8K words.Product name: N@@S1- type CPU Units with 40 I/O Points
CP1H-X40DT-D
Specifications: Power Supply, DC24V; Inputs, 24; Outputs, 16;
Output type: Transistor (sourcing).
Program capacity: 8K steps.
memory Data capacity: 8K words.
External powersupply(24 VDC): --.
Current consumption: 5 V, 0.31A; 24 V,0.02A.
Standards: CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient CP1H-X40DT-D HOST CONNECTION MANUAL.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Thermocouple Input Units.
points Input: 4 inputs CP1H-X40DT-D HOST CONNECTION MANUAL.
Signal range selection:
Set separately for each input.
I/O type: B, E, J, K, N, R, S, T, ±80mV.
Conversion speed: 150 ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.15A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and spacce compared,
with previous systems CP1H-X40DT-D Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CP1H-X40DT-D Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.