CPU Bus Cable (Expansion CPU Rack) 0.3 m (L) CV500-CN311Required for Analog Input and Output Units: For two Analog Units.Model: C500F-CPUA1-E(3G2C3-CPUA1-E).
C500F-CP CPU Programmable Controller C500F-CPUA1-E.For Hand-held Programming Console.
2m.Model: C200H-OD214.
No. of points: 8 pts.
Specifications: 0 CQM1H-CPU11 OPERATION Manual. 8 A, 24 VDC. source type (PNP). with load short protection.Name: Heat/Cool Temperature Control Module
CQM1H-CPU11
Model: C200H-TV002.
Sensor: Thermocouple: R, S, K, J, T, E, B, N, L, U.
Control output: Voltage output(transistor output used for cooling outputs).C500-RT SYSMAC BUS Remote I/O Master Slave Wired C500-RT002-V1.
PCF.With the optical connector 2Name: Host Link Module.
Model: C200H-LK101-PV1 CQM1H-CPU11 OPERATION Manual.
Communication ports: 1 fiber port.A Wide Range of Basic Input,
Units for High Speed Input and,
Different Applications.
Receive ON/OFF signals from external,
devices into the PLC System to update,
I/O memory in the CPU Unit.
New high-speed input models CJ1W-ID212 and,
CJ1W-ID233 are now available. These units can,
help to increase system throughput. Model: C200HW-ME16K.
Capacity: 16K words CQM1H-CPU11 OPERATION Manual. CPU Unit: CP1L-EM CPU Units with 40 Points.
Specifications: CPU type, Memory capacity: 10K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, DC power supply; Output method, Relay output;
Inputs, 24; Output, 16.
Standards: CE.
High Performing Programmable Controller with Embedded Ethernet.
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port.
"CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams. Unit type: CJ1 Special I/O Units.
Product name: Analog Input Unit.
I/O points: 8 inputs;
Signal range selection: 1 to 5 V, 0 to 5 V,
0 to 10 V, -10 to 10 V, 4 to 20mA;
1/4,000(Settable to 1/8,000)*2 .
Conversion period: 1 ms/point,
(250 μs/point can also be set.)*2.
Accuracy at ambient temperature of 25°C:
Voltage: ±0.2% of F. S. Current: ±0.4% of F.S.
External connecttion: Removable terminal block CQM1H-CPU11 Manual.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.42A; 24V, --.
Standards: UC1, N, L, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup.
Anaalog Input Units for converting analog input,
signals into binary data CQM1H-CPU11 Manual.
Analog Output Units for converting binary ,
data into analog output signals.