Model: C200H-PS211.
Supply voltage: 24VDC.Connecting I/O control module and interface module.
Cable length: 0.7 m.I/O points: 128 pts.
Program capacity(words): 3.2 K.
DM capacity (words): 1 K.
RS-232C port: YES.Connector: 100Base-TX.

Communications service: FINS communications service (TCP/IP, UDP/IP),
FTP server functions, socket services, mail transmission service,
mail receive (remote command receive),
automatically adjusted PLC built-in clock,
server/host name specification CS1W-CLK13 (H-PCF CABLE) Installation Guide CS1W-CLK13 (H-PCF CABLE) Model: C200HW-BI101-V1.
No. of I/O slots: 10 slots.Model: C200H-TS002.
Temperature sensor: Thermocou-ples: K (CA)/L (Fe-CuNi)(DIN)(selectable)
Input points: 4 points/Unit max. (1, 2, or 4 points can be selected)Protector for CPU bus connector CV500-COV01Specification: Thermocouple input, transistor (NPN) output, 2 loops CS1W-CLK13 (H-PCF CABLE) Installation Guide. Name: Clamp Terminal Blocks.
Specifications: Inputs/Outputs;
8 inputs/8 outputs ; PNP; --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system CS1W-CLK13 (H-PCF CABLE) Installation Guide.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Name: DeviceNet Master Module.
Model: C200HW-DRM21-V1.
Baud rate: 500, 250, or 125 kbps (selectable)

DeviceNet Master Unit
The DeviceNet Master Unit Is a Multi-vendor Bus Conforming to the DeviceNet.Unit type: CS1 Special I/O Units.
Product name: Isolated-type DC Input Unit.
Input points : 4 inputs.
Signal range: 4 to 20 mA, 0 to 20 mA,
0 to 10 V, ±10 V, 0 to 5 V, ±5 V,
1 to 5 V, 0 to 1.25 V, ±1.25 V.
Conversion speed (resolution):
20 ms/4 inputs, 10 ms/2 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 26V, 0.12A.
Standards: UC1, N, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems CS1W-CLK13 (H-PCF CABLE) Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CS1W-CLK13 (H-PCF CABLE) Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.
Related products