Power supply: DC power supply.
Output method: Transistor output sink type.
Inputs points: 12 points.
Outputs points: 8 points.Name: Host Link Module.
Model: C200H-LK202-V1.
Communication ports: 1 RS-422.Unit type: CS1 CPU Bus Units.
Product Name: MECHATROLINK-II,
compatible Position Control Unit.
Specifications: Control commands,
executed by MECHATROLINK-II,
synchronous communications CV1000-CPU01-V1 OPERATION MANUAL
CV1000-CPU01-V1
Direct operation by ladder,
programming, Control mode:
Position control, speed control,
or torque control; No. of axes: 2.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.36A; 26V, --.
Standards: UC1, CE.
Decrease TCO with Simple Operation,
Reduced Wiring, Batch Settings,
and Batch Management CV1000-CPU01-V1 OPERATION MANUAL.
Control Servos for up to 16 axes,
in a motion network with one Position,
Control Unit that supports MECHATROLINK-II.
MECHATROLINK-II is a registered trademark,
of the MECHATROLINK Members Association. 8 pts, 1 A, 120 VAC.Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Analog Output Unit.
Output points : 4 inputs.
Signal range selection:
Set separately for each input CV1000-CPU01-V1 OPERATION MANUAL.
Signal range: 0 to 10 V, ±10 V,
0 to 5 V, ±5 V, 0 to 1 V, ±1 V.
Conversion speed (resolution):
40ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 26V, 0.12A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space ccompared,
with previous systems CV1000-CPU01-V1 Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CV1000-CPU01-V1 Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.