I/O points: 256 pts.
Program capacity(words): 3.2 K.
DM capacity (words): 3 K.
RS-232C port: no.Model : CV500-CN228.
BASIC for connecting the unit ← → FIT10 (2m).I/O bits: 5, 120 (Expan-sion Racks: 7).
Program capacity: 20K steps.
Data memory capacity: 64K words (DM: 32K words, EM: 32K words ×1 banks) CV500-CPU01-EV1 Macro Reference. Unit type: CS-series Special I/O Units.
Product name: Analog Input Units
CV500-CPU01-EV1
Specifications: I/O points, 4 inputs;
Signal range selection,
Set separately for each input;
Signal range, 1 to 5 V, 0 to 5 V,
0 to 10 V, -10 V to 10 V, 4 to 20 mA;
Resolution, 1/8,000 (Settable to 1/4,000);
Conversion speed, 250 s/point max.
(Settable to 1 ms/point).
Externa connection, Removable terminal block CV500-CPU01-EV1 Macro Reference.
Current consumption: 5V, 0.12A; 26V, 0.09A.
Standards: UC1, N, CE.
For Various Analog I/Os.
Analog Input Units for converting,
analog input signals into binary data.
Analog Output Units for converting ,
binary data into analog output signals. Model : C500-LK203.
RS-232C/RS-422.Name: Three-tier Screw Terminal Block.
Specifications: Inputs; 16 inputs; NPN;
Without Short-circuit and,
Disconnected Line Detection CV500-CPU01-EV1 Macro Reference.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Model: CPM2A-40CDR-A. Power supply: AC power supply.
Output type: Relay.
Inputs points: 24 points.
Outputs points: 16 points.I/O bits: 960 (Expan-sion Racks: 2).
Program capacity: 20K steps.
Data memory capacity: 64K words (DM: 32K words, EM: 32K words ×1 bank)Unit classification: CJ1 Special I/O Units.
name: Position control unit.
Specifications; Control method/Control,
output interface:Open-loop control by pulse,
train output/Open-collector output;
Number of control axes : 1 axis.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0 CV500-CPU01-EV1 Manual. 25A; 24V, --.
Standards: UC1, CE.
High-speed, High-precision positioning,
with 1, 2, or 4 axes.
Versatile functions and superb performance,
enable the construction of compact,
high-performance machiines CV500-CPU01-EV1 Manual.
With its ultra-compact size of 31 × 90mm (W×H),
this highly space-efficient Position Control Unit,
(PCU) enables up to 4 axes of motor control.