OMRON
Home >> Download >> OMRON >> Manual Download >> CXONE-AL30D-V4 OPERATION MANUAL (CX-Motion-MCH)

CXONE-AL30D-V4 OPERATION MANUAL (CX-Motion-MCH)

Brand: OMRON
Product model: CXONE-AL30D-V4
Name: Host Link Units
Sort: OPERATION MANUAL (CX-Motion-MCH)
File language: English
File size: 2.25MB
Number of outputs: 8 pts.
Max. switch-ing capacity: 1.0 A at 24 V DC.
External connector: Terminal block.
Weight: 240 g max.Model: C200HS-INT01.
Rated Input Voltage: 12 to 24 VDC +10%/–15%.
Input Impedance: 2 K.
Input Current: 10 mA typical (24 VDC).
ON Voltage: 10.2 VDC min.
OFF Voltage: 3.0 VDC max CXONE-AL30D-V4 OPERATION MANUAL.
ON Response Time: 0.2 ms max.
OFF Response Time: 0.5 ms max.
No CXONE-AL30D-V4 of Circuits: CPU Unit: CP1L-L CPU Units with 14 Points.
Specifications: CPU type, Memory capacity: 5K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, AC power supply; Output method, Transistor output (sinking);
Inputs, 8; Output, 6.
Standards: UC1, N, L, CE CXONE-AL30D-V4 OPERATION MANUAL.
High Performing Programmable Controller with Embedded Ethernet.
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port.
"CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams. Model: C500-CN422.
C500-CN Cable Position Control Unit Connecting Cable: To connect C500-TU002-E 4m C500-CN422 CXONE-AL30D-V4 OPERATION MANUAL. Name: Heat/Cool Temperature Control Module.
Model: C200H-TV102.
Sensor: Platinum resistance thermometer: JPt100, Pt100.
Control output: Voltage output(transistor output used for cooling outputs).Model: CPM2A-20CDR-A. Power supply: AC power supply.
Output type: Relay.
Inputs points: 12 points.
Outputs points: 8 points.C500-ID Special I/O Unit ID Sensor Unit Long-distance C500-IDS02-V1.Inputs: 8.Name: High-speed Counter Module.
Model: C200H-CT021.
Number of axes: 2 axis/Unit.
Operating modes: 7.

High-speed Counter Unit
A High-speed Counter Unit counts input signals from incremental rotary encoders or other sources.Connects SYSMAC LINK Unit, Controller Link Unit to CPU Unit.
For 2 Unit.C500-ID I/O Unit DC Input 32 pts C500-ID218(3G2A5-ID218).
DC12-24V 10mA.Unit classification: CJ1 Special I/O Units.
Product name: Process Analog Input Units,
(Isolated-type Resistance Thermometer Input Units).
Input points: 4 inputs.
Signal range selection: Common inputs.
Signal range: Resistance thermometer: Pt100, JPt100.
Conversion speed (resolution): Conversion,
speed: 250 ms/4 inputs.
Accuracy at ambient temperature of 25°C:
Accuracy: (±0.3% of PV or ±0.8°C,
whichever is larger) ±1 digit max.
External connection: Removable terminal block.
No. of unit numbers allocated: 1.
Currrent consumption: 5V, 0 CXONE-AL30D-V4 Manual. 25A; 24V, --.
Standards: UC1, CE.
A Single Unit Handling All Types of Inputs,
such as Temperature Sensor Inputs and,
Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5V).
A Unit supports four inputt channels,
each of which can be set to a
platinum resistance thermometer, thermocouple,
and DC signal (current, voltage) CXONE-AL30D-V4 Manual.
All inputs are isolated.